CO-220 English Instruction Sheet
Page
2
W
Safety Information - Read First
⇒ Do not use the Meter as a personal safety monitor.
⇒ Learn and recognize the effects of CO poisoning.
0-1 PPM Normal background levels.
9 PPM ASHRAE Standard 62-1989 for living areas.
50 PPM OSHA enclosed space 8-hour average level.*
100 PPM OSHA exposure limit.*
200 PPM Mild headache, fatigue, nausea and dizziness.
800 PPM Dizziness, nausea and convulsions.
Death within 2 to 3 hours.
* U.S. Department of Labor, Occupational Safety & Health
Administration (OSHA) Regulation 1917.24:
The CO content in any
enclosed space shall be maintained at not more than 50 PPM
(0.005%). Remove employees from enclosed space if the CO
concentration exceeds 100 PPM (0.01 %).
What the Meter Does
The Meter indicates the presence of CO by a reading on the LCD
and a beeper tone.
Above 1000 PPM, the LCD reads “OL” to indicate an out of range
condition.
The beeper functions much like clicking of a Geiger counter:
• The higher the concentration of CO, the faster the beeper
sounds.
• Above 200 PPM, the beeper sounds continuously, while the
frequency of the tone increases with the concentration of CO.
Turning the Meter On
Install the battery. (See “Installing and Replacing the Battery.”)
To turn the Meter on, press the green button.
The Meter beeps twice, then performs a self-test. During the self-
test, the display counts down from “10” to “0”, while the Meter
emits a series of 2 beeps followed by a pause.
If the Meter passes the self-test, the Meter begins monitoring,
which is indicated by a beep every two seconds, and shows a
reading on the display.
Содержание
- Carbon monoxide meter 1
- Co 220 1
- Co 220 english instruction sheet page 1 1
- Contacting fluke 1
- Instruction sheet 1
- Introduction 1
- Co 220 english instruction sheet page 2 2
- Safety information read first 2
- Turning the meter on 2
- What the meter does 2
- Auto back light 3
- Automatic power off 3
- Co 220 english instruction sheet page 3 3
- Establishing a baseline 3
- Self test 3
- Storing maximum readings max hold 3
- Co 220 english instruction sheet page 4 4
- Muting the beeper 4
- Co 220 english instruction sheet page 5 5
- Common sources of co 5
- Installing and replacing the battery 5
- Co 220 english instruction sheet page 6 6
- Co and appliance malfunctions 6
- The following table identifies typical problems that can produce high levels of co 6
- Co 220 english instruction sheet page 7 7
- Specifications 7
- Any required adjustments are made at calibration to replace the sensor contact an authorized fluke service center 8
- Calibration or service 8
- Co 220 english instruction sheet page 8 8
- During normal use the meter does not require adjustment 8
- The meter should be calibrated once a year by an authorized fluke service center 8
- Warranty 8
Похожие устройства
- Fluke 975 AirMeter Data Sheet
- Fluke 975 AirMeter Положение об энергозависимости памяти
- Fluke 975 AirMeter Руководство по эксплуатации
- Fluke 975 AirMeter Reference Guide
- Fluke RLD2 Data Sheet
- Fluke 116 Положение об энергозависимости памяти
- Fluke 116 Multimeter Data Sheet
- Fluke 116 Extended Specs
- Fluke 116 Дополнение к информации о калибровке
- Fluke 116 DMM Selection Guide Brochure
- Fluke 116 Add wireless to your Fluke digital multimeter
- Fluke 116 Информация о калибровке
- Fluke 116 Руководство по эксплуатации
- Fluke 116С Руководство по эксплуатации
- Fluke 117 Положение об энергозависимости памяти
- Fluke 117 Дополнение к информации о калибровке
- Fluke 117 Информация о калибровке
- Fluke 115 Положение об энергозависимости памяти
- Fluke 115 Дополнение к информации о калибровке
- Fluke 115 Информация о калибровке