General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with
relative humidity at 0 % to 90 %.
Extended specifications are available at www.Fluke.com.
Maximum voltage between any
terminal and earth ground.......................... 600 V
Surge Protection ......................................... 6 kV peak per IEC 61010-1600V CAT III,
Pollution Degree 2
Display ......................................................... Digital: 6,000 counts, updates 4/sec
...................................................................... Bar Graph: 33 segments, updates 32/sec
Temperature ................................................ Operating: -10 °C to + 50 °C
Storage: -40 °C to + 60 °C
Temperature Coefficient............................. 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Operating Altitude....................................... 2,000 meters
Battery .......................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61
Battery Life .................................................. Alkaline: 400 hours typical, without backlight
Safety Compliances.................................... Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and
IEC/EN 61010-1 2
nd
Edition for measurement Category III,
600 V, Pollution Degree 2, EMC EN61326-1
Certifications............................................... UL,
P, CSA, TÜV, ;
(N10140), VDE
Содержание
58- Users manual
- True rms multimeter
- C true rms multimeter users manual
- Limited warranty and limitation of liability
- Unsafe voltage
- True rms multimeter
- Introduction
- Contacting fluke
- Safety information
- C users manual
- True rms multimeter safety information
- Display
- C users manual
- True rms multimeter display
- Terminals
- C users manual
- True rms multimeter rotary switch positions
- Rotary switch positions
- Min max avg recording mode
- Manual and autoranging
- Display hold
- C users manual
- Battery saver sleep mode
- Backlight
- True rms multimeter power up options
- Power up options
- Making basic measurements
- Testing for continuity
- Measuring resistance
- C users manual
- Using auto volts selection
- True rms multimeter making basic measurements
- Measuring ac and dc voltage
- Measuring ac and dc millivolts
- Measuring ac and dc current
- Flame sensor probe
- Control module
- C users manual
- Measuring temperature
- Measuring capacitance
- Measuring frequency
- Making low impedance capacitance measurements
- C users manual
- True rms multimeter making low impedance capacitance measurements
- Testing diodes
- Measuring current above 600 a
- Using the bargraph
- Replacing the battery
- Maintenance
- C users manual
- True rms multimeter cleaning
- Cleaning
- General specifications
- C users manual
- True rms multimeter general specifications
- C users manual
- True rms multimeter general specifications
- C users manual
Похожие устройства
-
Fluke 15b+Инструкция РУС -
Fluke 28 IIИнструкция по эксплуатации -
Fluke 87V с поверкойИнструкция по эксплуатации -
Fluke 106 с поверкойИнструкция по эксплуатации -
Fluke 117Extended Specs -
Fluke 117Информация о калибровке -
Fluke 117Дополнение к информации о калибровке -
Fluke 117Положение об энергозависимости памяти -
Fluke 116Руководство по эксплуатации -
Fluke 116Информация о калибровке -
Fluke 116Add wireless to your Fluke digital multimeter -
Fluke 116DMM Selection Guide Brochure
Узнайте о точности, температурных диапазонах и других характеристиках измерительных приборов. Подробные спецификации и требования к безопасности.