Fluke 718 ex [2/6] Change 1 51120

Fluke 718 ex [2/6] Change 1 51120
718Ex 30G/100G/300G Users Manual Supplement
10/17 1
Change #1, 51120
On page 27, add the following section under the Entity Parameters:
Pressure Module Output Circuit:
Vo, Uo Io Po
Co Lo
IIC IIB IIA IIC IIB IIA
7.14 V 102 mA 182 mW 13.5 µF 240 µF 1000 µF 3.4 mH 10.2 mH 27.2 mH
Change #2, 52975
On page 9, under Certification Information, change the following:
From: II 1 G EEx ia IIC T4
To: II 1 G Ex ia IIC T4
Change #8 superecedes the portion of this change listed below.
On page 27, under Product Compliance Markings, change the following:
From: II 1 G EEx ia IIC T4
0344 KEMA 04ATEX1601 X
To: II 1 G Ex ia IIC T4
0344 KEMA 04ATEX1601 X