Kospel Primus EPJ 5,5 [18/32] Faults

Kospel Primus EPJ 5,5 [18/32] Faults
18
Faults
Incasetheheaterdoesnotheatthewater,checkforpossiblereasons:
- afailureofthemainssupplies(e.g.fuses),
- insufcientowratethroughtheheater(e.g.dirtylter,incorrectsettingofthe
owregulatingvalve)-see„Flowregulation”.
Thewarrantydoesnotcovertheaboverepairs.
Ifthereisafaultintheappliance(theheaterdoesnotworkandalltheabovereasons
donotoccur),contacttheseller.
Technical data
EPJ.P-......-shower
EPJ.P-....u-shower+washbasin
Water heater EPJ.P Primus 4,4 5,5
Ratedpower kW 4,4 5,5
Ratedvoltage 230V~
Ratedcurrent A 19,1 23,9
Min.supplywaterpressure MPa 0,12
Safetyclass IP25
Operatingpoint l/min 1,8 2,2
Efciency(atΔt=30°C) l/min 2,1 2,7
Overalldimension(heightwithouttapsetxwidthxdepth)
mm 218x214x95
Weight(heater+ttings) kg 2,2÷0,6
Connectiontothemainsbysupplycord(1,2m) mm
2
3x2,5
Themaximumallowednetworkimpedance 0,44 0,31
Watersupplypipesection G1/2"