Tp-Link T2600G-52TS V3 [165/549] Switchport dot1q tunnel missdrop

Tp-Link T2600G-52TS V3 [165/549] Switchport dot1q tunnel missdrop
142
19.5 switchport dot1q-tunnel missdrop
Note:
For T2600G-28TS/T2600G-28MPS/T2600G-28SQ/T2600G-52TS, Missdrop can only be
enabled on UNI ports.
For T2600G-18TS, Missdrop can only be enabled on NNI ports.
Description
The switchport dot1q-tunnel missdrop command is used to enable the
VLAN-VPN missdrop function for a specific port. To disable the VLAN-VPN
missdrop function, please use the no switchport dot1q-tunnel missdrop
command.
Syntax
switchport dot1q-tunnel missdrop
no switchport dot1q-tunnel missdrop
Command Mode
Interface Configuration Mode (interface gigabitEthernet / interface range
gigabitEthernet / interface port-channel / interface range port-channel)
Privilege Requirement
Only Admin, Operator and Power User level users have access to these
commands.
Example
Enable the VLAN-VPN missdrop function for Gigabit Ethernet port 1/0/3:
T2600G-28TS(config)#interface gigabitEthernet 1/0/3
T2600G-28TS(config-if)#switchport dot1q-tunnel missdrop
19.6 switchport dot1q-tunnel use_inner_priority
Description
The switchport dot1q-tunnel use_inner_priority command is used to use
the inner 802.1p priority. To disable this function, please use the no
switchport dot1q-tunnel use_inner_priority command.