Tp-Link T2600G-52TS V3 [473/549] Command mode

Tp-Link T2600G-18TS V2 [473/549] Command mode
450
port
——The number of the udp port which is selected for the sFlow
collector.
maxData
——Specify the maximum number of data bytes that can be sent in
a single sample datagram. The value ranges from 300 to 1400 and the default
value is 300 bytes.
timeout
——Specify the aging time of the sFlow collector, ranging from 0 to
2000000 seconds. When the timeout is set to 0, it means the life cycle of the
collector is infinite.
Command Mode
Global Configuration Mode
Privilege Requirement
Only Admin and Operator level users have access to these commands.
Example
Specify the ip of the sFlow collector 1 as 192.168.0.100, the port as 3000:
T2600G-28TS(config)# sflow collector collector-ID 1 ip 192.168.0.100
T2600G-28TS(config)# sflow collector collector-ID 1 port 3000
55.4 sflow sampler
Description
The sflow sampler command is used to configure the parameters about the
sFlow sampler.
Syntax
sflow sampler { [ collector-ID
value
] | [ ingRate
ingress-rate
] [ egRate
egress-rate
] | [ maxHeader
maxHeader
] }
Parameter
value
—— The ID of the sFlow collector which the sFlow sampler will send
sFlow datagrams to. The value ranges from 0 to 4. When the value is zero, it
means no collector is selected.
ingress-rate
——Specify the ingress sampling frequency of the sFlow
sampler. When a sample is taken, the value indicates how many packets to
skip before the next sample is taken. The value ranges from 1024 to 65535
and the default value is 0 which means no packets will be sampled.
egress-rate
——Specify the egress sampling frequency of the sFlow sampler.
When a sample is taken, the value indicates how many packets to skip before