Tp-Link T2600G-28MPS V4 [1062/1124] Using the cli

Tp-Link T2600G-28MPS V4 [1062/1124] Using the cli
Configuring SNMP & RMON Notification Configurations
Configuration Guide
1033
DDM Voltage Only T2600G-28TS supports DDM traps. Monitors the voltage of SFP
modules inserted into the SFP ports on the switch. The trap can be triggered
when the voltage of any SFP module has reached the warning or alarm
threshold.
DDM Bias Current Only T2600G-28TS supports DDM traps. Monitors the bias current of SFP
modules inserted into the SFP ports on the switch. The trap can be triggered
when the bias current of any SFP module has reached the warning or alarm
threshold.
DDM TX Power Only T2600G-28TS supports DDM traps. Monitors the TX Power of SFP
modules inserted into the SFP ports on the switch. The trap can be triggered
when the TX Power of any SFP module has reached the warning or alarm
threshold.
DDM RX Power Only T2600G-28TS supports DDM traps. Monitors the RX Power of SFP
modules inserted into the SFP ports on the switch. The trap can be triggered
when the RX Power of any SFP module has reached the warning or alarm
threshold.
ACL Counter Monitors matched ACL information, including the matched ACL ID, rule ID
and the number of the matched packets. With both this trap and the Logging
feature in ACL rule settings enabled, the switch will check the matched ACL
information every five minutes and send SNMP traps if there is any updated
information.
2) Click Apply.
3.2 Using the CLI
3.2.1 Configuring the NMS Host
Configure parameters of the NMS host and packet handling mechanism.
Step 1 configure
Enter global configuration mode.