Configuring DDM DDM Configuration
Configuration Guide
157
Follow these steps to configure DDM‘s voltage threshold:
1) In the Port Config table, configure voltage threshold on the SFP ports.
High Alarm Specify the high threshold for the alarm. When the operating parameter rises
above this value, action associated with the alarm will be taken. The valid values
are from 0 to 6.5535.
Low Alarm Specify the low threshold for the alarm. When the operating parameter falls below
this value, action associated with the alarm will be taken. The valid values are from
0 to 6.5535.
High Warning Specify the high threshold for the warning. When the operating parameter rises
above this value, action associated with the warning will be taken. The valid values
are from 0 to 6.5535.
Low Warning Specify the low threshold for the warning. When the operating parameter falls
below this value, action associated with the warning will be taken. The valid values
are from 0 to 6.5535.
LAG Displays the LAG number which the port belongs to.
2) Click Apply
.
2.1.4 Configuring the Bias Current Threshold
Choose the menu Switching > DDM > Bias Current Threshold to load the following page.
Figure 2-4 Configure Bias Current Threshold
Follow these steps to configure DDM‘s bias current threshold:
1) In the Port Config table, configure bias current threshold on the SFP ports.
High Alarm Specify the high threshold for the alarm. When the operating parameter rises
above this value, action associated with the alarm will be taken. The valid values
are from 0 to 131.
Low Alarm Specify the low threshold for the alarm. When the operating parameter falls below
this value, action associated with the alarm will be taken. The valid values are from
0 to 131.
High Warning Specify the high threshold for the warning. When the operating parameter rises
above this value, action associated with the warning will be taken. The valid values
are from 0 to 131.