Rigol MSO5104 [166/360] Count values
Превью страниц
Страница 166 /
360
![Rigol MSO5104 [166/360] Count values](/views2/1472896/page166/bga6.png)
RIGOL Chapter 6 Operations and Measurements
6-30 MSO5000 User's Guide
6. -Width: indicates the time between the threshold middle value of a falling edge
to the threshold middle value of the next rising edge.
7. +Duty: indicates the ratio of the positive pulse width to the period.
8. -Duty:indicates the ratio of the negative pulse width to the period.
9. Tvmax: indicates the time that corresponds to the maximum value of the
waveform (Vmax).
10. Tvmin: indicates the time that corresponds to the minimum value of the
waveform (Vmin).
Note: The default values for threshold upper limit, threshold middle value, and
threshold low limit are 90%, 50%, and 10%, respectively. You can press Measure
Setting to enter the sub-menu to set the parameters.
Count Values
1. Positive Pulse Count: The number of positive pulses that rise from under the
threshold lower limit to above the threshold upper limit.
2. Negative Pulse Count: The number of negative pulses that fall from above
the threshold upper limit to below the threshold lower limit.
3. Rising Edge Count: The number of rising edges that rise from under the
threshold lower limit to above the threshold upper limit.
Positive Pulse Count = n
1 2 n
Negative Pulse Count = n
1 2 n
Threshold Upper Limit
Threshold Lower Limit
Threshold Upper Limit
Threshold Lower Limit
Содержание
340- Feb 2019 rigol suzhou technologies inc
- User s guide mso5000 series digital oscilloscope
- Notices
- Guaranty and declaration
- Copyright
- Contact us
- Trademark information
- Software version
- Publication number
- Product certification
- Safety requirement
- General safety summary
- Safety notices and symbols
- Measurement category
- Ventilation requirement
- Working environment
- Care and cleaning
- Environmental considerations
- Mso5000 series overview
- Main topics of this manual
- Document overview
- Content conventions in this manual
- Format conventions in this manual
- Manuals of this product
- Contents
- Quick start
- Chapter 1 quick start
- General inspection
- Appearance and dimensions
- To prepare for use
- To connect to ac power
- To adjust the supporting legs
- Turn on checkout
- To connect the probe
- Function inspection
- Probe compensation
- Front panel overview
- Rear panel overview
- Front panel function overview
- Vertical
- Horizontal
- Trigger
- Function menu
- Quick key shortcut key
- Navigation control key
- Single
- Run stop
- Function arbitrary waveform generator setting
- Touch lock key
- Multifunction knob
- Default
- User interface
- Touch screen controls
- Pinch stretch
- Rectangle drawing
- Parameter setting method
- To use the kensington security lock
- To use the built in help system
- To view the option information and the option installation
- To set the vertical system
- Chapter 2 to set the vertical system
- To enable or disable the analog channel
- To adjust the vertical scale
- Vertical expansion
- To adjust the vertical offset
- Channel coupling
- Bandwidth limit
- Probe ratio
- Waveform invert
- Input impedance
- Channel delay
- Amplitude unit
- Offset cal
- Channel label
- To set the horizontal system
- Chapter 3 to set the horizontal system
- To adjust the horizontal time base
- To adjust the horizontal position
- Delayed sweep
- To set the sample system
- Chapter 4 to set the sample system
- Yt mode
- Xy mode
- Timebase mode
- Roll mode
- Acquisition mode
- Normal
- Average
- Sample rate
- Sampling mode
- High resolution
- Memory depth
- La sample rate
- La memory depth
- Horizontal expansion
- Anti aliasing
- Reset the user defined reference position to 0
- Note this function is unavailable in yt mode with the delayed sweep being enabled xy mode and roll mode
- To trigger the oscilloscope
- Chapter 5 to trigger the oscilloscope
- Trigger source
- Trigger level threshold level
- Trigger mode
- Trigger coupling
- Trigger holdoff
- Noise rejection
- Trigger type
- Edge trigger
- Pulse trigger
- Slope trigger
- Video trigger
- Pattern trigger
- Duration trigger
- Timeout trigger
- Time out
- T time out t
- Runt trigger
- Window trigger
- Delay trigger
- Setup hold trigger
- Nth edge trigger
- Rs232 trigger option
- I2c trigger option
- Spi trigger option
- Can trigger option
- Flexray trigger option
- Lin trigger option
- I2s trigger option
- Mil std 1553 trigger option
- Zone trigger
- Trigger output connector
- Operations and measurements
- Chapter 6 operations and measurements
- Addition
- Math operation
- Subtraction
- Multiplication
- Division
- And operation
- Or operation
- Xor operation
- Not operation
- Lg base 10 exponential
- Low pass
- High pass
- Band pass
- Band stop
- Math operation label
- Quick measurement after auto
- Auto measurement
- Time parameters
- Measurement parameter
- Count values
- Delay and phase
- Period b delaya b phasea
- B phasea
- B delaya
- Voltage parameters
- Measurement settings
- Statistical function
- Remove the measurement result
- Cursor measurement
- All measurement
- Manual mode
- Track mode
- Xy mode
- Measure mode
- Digital voltmeter dvm and frequency counter
- Chapter 7 digital voltmeter dvm and frequency counter
- To select the measurement source
- To enable or disable dvm measurement
- Digital voltmeter dvm
- To set the limits
- To select measurement mode
- To select the measurement source
- To select the measurement item
- To enable or disable the frequency counter
- Frequency counter
- To set resolution
- To enable or disable the statistical function
- To clear count
- Chapter 8 power analysis option
- Power analysis option
- Power quality
- Ripple
- Histogram analysis
- Chapter 9 histogram analysis
- To select the histogram type
- To enable or disable the histogram function
- To set the histogram range
- To set the histogram height
- To select the histogram source
- To enable or disable the statistical function
- To reset
- Digital channel
- Chapter 10 digital channel
- To select the digital channel
- To enable disable the digital channel
- To set the threshold and calibrate probe
- To set the waveform display size
- To set the label
- Auto arrangement setting
- Group setting
- Waveform color of the digital channel
- Protocol decoding
- Chapter 11 protocol decoding
- Parallel decoding
- Rs232 decoding option
- Stop bit
- Start bit
- Data bit
- Check bit
- I2c decoding option
- Spi decoding option
- Lin decoding option
- Can decoding option
- Flexray decoding option
- I2s decoding option
- B decoding option
- Reference waveform
- Chapter 12 reference waveform
- To select the reference channel
- To select the ref source
- To enable ref function
- To adjust the ref waveform display
- To view details of the reference waveform
- To save to internal memory
- To clear the display of the reference waveform
- Label setting
- Color setting
- To reset the reference waveform
- To import from internal or external memory
- To export to internal or external memory
- Pass fail test
- Chapter 13 pass fail test
- To start or stop the pass fail test operation
- To select the source
- To enable or disable the pass fail test function
- To save the mask
- To load a mask
- To create a mask
- To set the output form of the test results
- To enable or disable the display of the statistics of the test results
- Statistics reset
- Waveform recording playing
- Chapter 14 waveform recording playing
- Common settings
- Record options
- Play options
- Search and navigation function
- Chapter 15 search and navigation function
- Search function
- Navigation function
- To navigate to the next event the serial number in the mark table increases the
- Number in the mark table decreases press
- Key is disabled in the event navigation
- Display control
- Chapter 16 display control
- To set the persistence time
- To select the display type
- To set the waveform intensity
- To set the screen grid
- Waveform freeze
- To set the grid brightness
- Screen saver
- Color grade
- Function arbitrary waveform generator option
- Chapter 17 function arbitrary waveform generator option
- To output sine
- To output basic waveforms
- To output square
- To output ramp
- To output pulse
- To output noise
- To output dc
- Exp rise
- Exp fall
- Lorentz
- To output the arbitrary waveform
- To load the channel and waveform
- Haversine
- To create the waveform
- To edit waveforms
- Modulation
- Store and load
- Chapter 18 store and load
- Storage type
- Storage system
- Load type
- Internal storage and load
- External storage and load
- Disk management
- To select a file type
- To create a folder
- English input method
- Simplified chinese or traditional chinese input method
- To delete a file or folder
- To rename a file or folder
- To copy and paste a file or folder
- File or directory exists is displayed you are not allowed to execute the copy and paste operation
- To clear the internal memory safely
- Factory settings
- System utility function setting
- Chapter 19 system utility function setting
- Lan configuration
- Remote interface configuration
- Network status
- Ip configuration type
- Mac address
- Apply the network parameter setting
- Visa address
- To set mdns
- To set hdmi
- Usb connection
- To set the gpib address
- System related
- System information
- Power on
- Language
- Beeper
- Aux output
- Self calibration
- Auto config
- Print setting
- Key locker
- Quick operation
- Self check
- System time
- Remote control
- Chapter 20 remote control
- Remote control via usb
- Remote control via lan
- Remote control via gpib
- Troubleshooting
- Chapter 21 troubleshooting
- Chapter 22 appendix
- Appendix a accessories and options
- Appendix
- Note for all the mainframes accessories and options please contact the local office of rigol
- Appendix b warranty
Похожие устройства
-
Rigol DS1204BИнструкция по эксплуатации(ENG) -
Rigol DS1104BИнструкция по эксплуатации(ENG) -
Rigol DS1074BИнструкция по эксплуатации(ENG) -
Rigol DS1052DИнструкция по эксплуатации(ENG) -
Rigol DS1102DИнструкция по эксплуатации(ENG) -
Rigol DS1052EИнструкция по эксплуатации(ENG) -
Rigol DS1102EИнструкция по эксплуатации(ENG) -
Rigol DS6062Инструкция по эксплуатации(ENG) -
Rigol DS6064Инструкция по эксплуатации(ENG) -
Rigol DS6102Инструкция по эксплуатации(ENG) -
Rigol DS6104Инструкция по эксплуатации(ENG) -
Rigol DS4012Инструкция по эксплуатации(ENG)