Chapter 6 Operations and Measurements RIGOL
MSO5000 User's Guide 6-35
reference is negative. The area measured is the algebraic sum of the whole
period area.
Measurement Settings
1. Measurement Category
Press Measure Add Category to select "Horizontal", "Vertical", or
"Other". Meanwhile, the specific measurement parameters are displayed on the
screen, as shown in the figure below. In the measurement category area, you
can also rotate the multifunction knob
to select "Horizontal", "Vertical", or
"Other". Then press down the knob to switch to the desired measurement
category.
"Horizontal" measurement parameters: Period, Freq, RiseTime, FallTime,
+Width, -Width, +Duty, -Duty, +Pulses, -Pulses, +Edges, -Edges, Tvmax,
Tvmin, +SlewRate, and –SlewRate.
"Vertical" measurement parameters: Vmax, Vmin, Vpp, Vtop, Vbase, Vamp,
Vmid, Vlower, Vavg, VRMS, Per.VRMS, Overshot, Preshoot, Area, Per.Area,
and Variance.
"Other" measurement parameters: Delay(A
→B ), Delay(A →B ),
Delay(A
→B ), Delay(A →B ), Phase(A →B ), Phase(A →B ),
Phase(A
→B ), and Phase(A →B ).
In the measurement parameter area, rotate the multifunction knob to select
a measurement item and then press down the knob to select it. Then the
measurement results of the item are displayed at the bottom of the screen
(measurement results of up to 10 items can be displayed at most). When you
add a new measurement item, its measurement result will be displayed as the
first, with the original items moving right in sequence. If the number of
measurement items added exceeds 10, then when you add one item, the
rightmost item at the bottom of the screen will be disabled. You can also enable
the touch screen to select the measurement category and the measurement
Measurement Category Area Measurement Parameter Area
Содержание
340- Feb 2019 rigol suzhou technologies inc
- User s guide mso5000 series digital oscilloscope
- Notices
- Guaranty and declaration
- Copyright
- Contact us
- Trademark information
- Software version
- Publication number
- Product certification
- Safety requirement
- General safety summary
- Safety notices and symbols
- Measurement category
- Ventilation requirement
- Working environment
- Care and cleaning
- Environmental considerations
- Mso5000 series overview
- Main topics of this manual
- Document overview
- Content conventions in this manual
- Format conventions in this manual
- Manuals of this product
- Contents
- Quick start
- Chapter 1 quick start
- General inspection
- Appearance and dimensions
- To prepare for use
- To connect to ac power
- To adjust the supporting legs
- Turn on checkout
- To connect the probe
- Function inspection
- Probe compensation
- Front panel overview
- Rear panel overview
- Front panel function overview
- Vertical
- Horizontal
- Trigger
- Function menu
- Quick key shortcut key
- Navigation control key
- Single
- Run stop
- Function arbitrary waveform generator setting
- Touch lock key
- Multifunction knob
- Default
- User interface
- Touch screen controls
- Pinch stretch
- Rectangle drawing
- Parameter setting method
- To use the kensington security lock
- To use the built in help system
- To view the option information and the option installation
- To set the vertical system
- Chapter 2 to set the vertical system
- To enable or disable the analog channel
- To adjust the vertical scale
- Vertical expansion
- To adjust the vertical offset
- Channel coupling
- Bandwidth limit
- Probe ratio
- Waveform invert
- Input impedance
- Channel delay
- Amplitude unit
- Offset cal
- Channel label
- To set the horizontal system
- Chapter 3 to set the horizontal system
- To adjust the horizontal time base
- To adjust the horizontal position
- Delayed sweep
- To set the sample system
- Chapter 4 to set the sample system
- Yt mode
- Xy mode
- Timebase mode
- Roll mode
- Acquisition mode
- Normal
- Average
- Sample rate
- Sampling mode
- High resolution
- Memory depth
- La sample rate
- La memory depth
- Horizontal expansion
- Anti aliasing
- Reset the user defined reference position to 0
- Note this function is unavailable in yt mode with the delayed sweep being enabled xy mode and roll mode
- To trigger the oscilloscope
- Chapter 5 to trigger the oscilloscope
- Trigger source
- Trigger level threshold level
- Trigger mode
- Trigger coupling
- Trigger holdoff
- Noise rejection
- Trigger type
- Edge trigger
- Pulse trigger
- Slope trigger
- Video trigger
- Pattern trigger
- Duration trigger
- Timeout trigger
- Time out
- T time out t
- Runt trigger
- Window trigger
- Delay trigger
- Setup hold trigger
- Nth edge trigger
- Rs232 trigger option
- I2c trigger option
- Spi trigger option
- Can trigger option
- Flexray trigger option
- Lin trigger option
- I2s trigger option
- Mil std 1553 trigger option
- Zone trigger
- Trigger output connector
- Operations and measurements
- Chapter 6 operations and measurements
- Addition
- Math operation
- Subtraction
- Multiplication
- Division
- And operation
- Or operation
- Xor operation
- Not operation
- Lg base 10 exponential
- Low pass
- High pass
- Band pass
- Band stop
- Math operation label
- Quick measurement after auto
- Auto measurement
- Time parameters
- Measurement parameter
- Count values
- Delay and phase
- Period b delaya b phasea
- B phasea
- B delaya
- Voltage parameters
- Measurement settings
- Statistical function
- Remove the measurement result
- Cursor measurement
- All measurement
- Manual mode
- Track mode
- Xy mode
- Measure mode
- Digital voltmeter dvm and frequency counter
- Chapter 7 digital voltmeter dvm and frequency counter
- To select the measurement source
- To enable or disable dvm measurement
- Digital voltmeter dvm
- To set the limits
- To select measurement mode
- To select the measurement source
- To select the measurement item
- To enable or disable the frequency counter
- Frequency counter
- To set resolution
- To enable or disable the statistical function
- To clear count
- Chapter 8 power analysis option
- Power analysis option
- Power quality
- Ripple
- Histogram analysis
- Chapter 9 histogram analysis
- To select the histogram type
- To enable or disable the histogram function
- To set the histogram range
- To set the histogram height
- To select the histogram source
- To enable or disable the statistical function
- To reset
- Digital channel
- Chapter 10 digital channel
- To select the digital channel
- To enable disable the digital channel
- To set the threshold and calibrate probe
- To set the waveform display size
- To set the label
- Auto arrangement setting
- Group setting
- Waveform color of the digital channel
- Protocol decoding
- Chapter 11 protocol decoding
- Parallel decoding
- Rs232 decoding option
- Stop bit
- Start bit
- Data bit
- Check bit
- I2c decoding option
- Spi decoding option
- Lin decoding option
- Can decoding option
- Flexray decoding option
- I2s decoding option
- B decoding option
- Reference waveform
- Chapter 12 reference waveform
- To select the reference channel
- To select the ref source
- To enable ref function
- To adjust the ref waveform display
- To view details of the reference waveform
- To save to internal memory
- To clear the display of the reference waveform
- Label setting
- Color setting
- To reset the reference waveform
- To import from internal or external memory
- To export to internal or external memory
- Pass fail test
- Chapter 13 pass fail test
- To start or stop the pass fail test operation
- To select the source
- To enable or disable the pass fail test function
- To save the mask
- To load a mask
- To create a mask
- To set the output form of the test results
- To enable or disable the display of the statistics of the test results
- Statistics reset
- Waveform recording playing
- Chapter 14 waveform recording playing
- Common settings
- Record options
- Play options
- Search and navigation function
- Chapter 15 search and navigation function
- Search function
- Navigation function
- To navigate to the next event the serial number in the mark table increases the
- Number in the mark table decreases press
- Key is disabled in the event navigation
- Display control
- Chapter 16 display control
- To set the persistence time
- To select the display type
- To set the waveform intensity
- To set the screen grid
- Waveform freeze
- To set the grid brightness
- Screen saver
- Color grade
- Function arbitrary waveform generator option
- Chapter 17 function arbitrary waveform generator option
- To output sine
- To output basic waveforms
- To output square
- To output ramp
- To output pulse
- To output noise
- To output dc
- Exp rise
- Exp fall
- Lorentz
- To output the arbitrary waveform
- To load the channel and waveform
- Haversine
- To create the waveform
- To edit waveforms
- Modulation
- Store and load
- Chapter 18 store and load
- Storage type
- Storage system
- Load type
- Internal storage and load
- External storage and load
- Disk management
- To select a file type
- To create a folder
- English input method
- Simplified chinese or traditional chinese input method
- To delete a file or folder
- To rename a file or folder
- To copy and paste a file or folder
- File or directory exists is displayed you are not allowed to execute the copy and paste operation
- To clear the internal memory safely
- Factory settings
- System utility function setting
- Chapter 19 system utility function setting
- Lan configuration
- Remote interface configuration
- Network status
- Ip configuration type
- Mac address
- Apply the network parameter setting
- Visa address
- To set mdns
- To set hdmi
- Usb connection
- To set the gpib address
- System related
- System information
- Power on
- Language
- Beeper
- Aux output
- Self calibration
- Auto config
- Print setting
- Key locker
- Quick operation
- Self check
- System time
- Remote control
- Chapter 20 remote control
- Remote control via usb
- Remote control via lan
- Remote control via gpib
- Troubleshooting
- Chapter 21 troubleshooting
- Chapter 22 appendix
- Appendix a accessories and options
- Appendix
- Note for all the mainframes accessories and options please contact the local office of rigol
- Appendix b warranty
Похожие устройства
-
Rigol DS1204BИнструкция по эксплуатации(ENG) -
Rigol DS1104BИнструкция по эксплуатации(ENG) -
Rigol DS1074BИнструкция по эксплуатации(ENG) -
Rigol DS1052DИнструкция по эксплуатации(ENG) -
Rigol DS1102DИнструкция по эксплуатации(ENG) -
Rigol DS1052EИнструкция по эксплуатации(ENG) -
Rigol DS1102EИнструкция по эксплуатации(ENG) -
Rigol DS6062Инструкция по эксплуатации(ENG) -
Rigol DS6064Инструкция по эксплуатации(ENG) -
Rigol DS6102Инструкция по эксплуатации(ENG) -
Rigol DS6104Инструкция по эксплуатации(ENG) -
Rigol DS4012Инструкция по эксплуатации(ENG)
Узнайте, как настраивать параметры измерений в руководстве пользователя. Выберите категории измерений и просматривайте результаты на экране устройства.