Beko CWB6410AR Руководство пользователя онлайн [11/76] 397340

Содержание

2 Drill eight 8 mm holes on the points X Y X2 X1 and place plastic plugs supplied with the packaging Check whether the holes of the flue connection parts correspond to these holes or not 3 As shown in Figure 2 fix connectors C to the holes X1 and X2 via two fixing screws supplied with the accessories Screw distance ring D on the Y hole as small diameter side facing the wall 4 Install the hood from the key hole on back plate onto the distance ring and pull downward to make sure that it is secured Then screw the body onto the wall from the holes J1 and J2 on the upper back of the body To avoid the hood falling down accidentally for any reason screw it also from the hole J3 shown in Figure 3 5 As shown in Figure 4 place chimney outlet flange E to the rectangular outlet on the upper part of the hood and screw the flange onto the body using 2 9 mm traced screws supplied with accessories 6 For chimney connection usage In chimney connected position absorbed air will go through oil filters to the outlet and then will reach to the chimney though connection pipes and finally thrown out from the chimney When using this connection position 150mm to 120 mm E connector should be installed on chimney outlet flange as shown in Figure 5 Chimney connection pipes must be made of fireproof plastic material When using flexible connection type it should be considered that sharp corners and sudden contractions will have a negative impact on air suction Flue connection should in no way be made to any flue to which another device was already connected for another purpose 11 EN