Daikin FWC12AT [14/26] Capacity tables

Daikin FWC05AF [14/26] Capacity tables
Fan coil units • Ceiling mounted cassette unit • FWC
1
4
• Fan coil units • Ceiling mounted cassette unit • FWC
12
4 Capacity tables
4 - 3 Heating capacity tables
Air temperature (°C DB - °C WB) 20
Water temperature (Entering °C - Leaving °C) 50 - 45 60 - 50 70 - 60
Model
Air Flow
m
3
/hr
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
FWC02AF
High
8.99 1.54 14.26 9.57 0.82 4.11 10.55 0.91 4.77
Medium
8.551.4612.949.050.783.699.990.864.30
Low
8.211.4111.988.650.743.399.560.823.95
FWC03AF
High
9.26 1.59 16.03 9.96 0.86 4.71 10.99 0.94 5.47
Medium
8.60 1.47 13.92 9.12 0.78 3.98 10.08 0.87 4.64
Low
8.311.4213.008.750.753.679.680.834.29
FWC04AF
High
11.14 1.91 23.46 11.27 0.97 6.13 12.50 1.08 7.20
Medium
9.87 1.69 18.58 9.89 0.85 4.76 10.97 0.94 5.60
Low
9.48 1.62 17.18 9.46 0.81 4.38 10.51 0.90 5.15
FWC05AF
High
12.06 2.07 28.23 12.15 1.05 7.31 13.48 1.16 8.59
Medium
11.21 1.92 24.53 11.23 0.97 6.28 12.46 1.07 7.39
Low
10.58 1.81 21.95 10.56 0.91 5.58 11.72 1.01 6.56
FWC06AF
High
12.43 2.13 29.68 12.42 1.07 7.56 13.78 1.19 8.88
Medium
11.59 1.99 25.91 11.55 0.99 6.57 12.82 1.10 7.73
Low
10.90 1.87 23.02 10.83 0.93 5.81 12.03 1.04 6.84
Air temperature (°C DB - °C WB) 22
Water temperature (Entering °C - Leaving °C) 50 - 45 60 - 50 70 - 60
Model
Air Flow
m
3
/hr
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
Heating
capacity
kW
Water
flow
m
3
/hr
Water
pressure
drop
kPa
FWC02AF
High
8.45 1.45 12.67 9.06 0.78 3.70 10.11 0.87 4.40
Medium
8.041.3811.518.560.743.329.560.823.95
Low
7.731.3210.668.180.703.049.150.793.63
FWC03AF
High
8.74 1.50 14.36 9.42 0.81 4.24 10.52 0.91 5.04
Medium
8.121.3912.448.630.743.579.650.834.27
Low
7.831.3411.618.260.713.299.260.803.94
FWC04AF
High
10.43 1.79 20.67 10.64 0.92 5.49 11.95 1.03 6.59
Medium
9.24 1.58 16.34 9.33 0.80 4.26 10.48 0.90 5.13
Low
8.87 1.52 15.11 8.93 0.77 3.91 10.03 0.86 4.71
FWC05AF
High
11.29 1.93 24.87 11.47 0.99 6.54 12.88 1.11 7.87
Medium
10.49 1.80 21.58 10.60 0.91 5.62 11.91 1.02 6.76
Low
9.90 1.70 19.30 9.96 0.86 4.99 11.19 0.96 6.00
FWC06AF
High
11.60 1.99 25.96 11.72 1.01 6.76 13.17 1.13 8.14
Medium
10.82 1.85 22.70 10.90 0.94 5.87 12.25 1.05 7.08
Low
10.18 1.74 20.18 10.22 0.88 5.19 11.49 0.99 6.26
Heating capacities FWC-F (4 pipe)

Содержание

Скачать