Dometic TEC 30EV [23/360] Preparing maintenance work

Dometic TEC 30EV [23/360] Preparing maintenance work
EN
TEC30D EV Servicing the generator
23
10.2 Preparing maintenance work
!
Open the generator cover (fig. 4 2, page 5).
Switch the generator to no function with the main switch (fig. 4 1, page 5).
10.3 Finishing maintenance work
Switch the generator to standby with the main switch (fig. 4 1, page 5).
Close the generator cover (fig. 4 2, page 5).
Interval Inspection/maintenance
In the first month
or after 50 hours
Change the oil (chapter “Changing the oil” on page 24).
Every 3 months or
every 50 hours
Check and clean the air filter (chapter “Servicing the air filter” on
page 25).
Every 250 hours Change the oil (chapter “Changing the oil” on page 24).
Clean the motor‘s cooling devices.
Check the valves.
Check if the screws are intact and firmly tightened.
Every 500 hours Replace the fuel filter (chapter “Changing the fuel filter” on
page 25).
Replace the air filter (chapter “Servicing the air filter” on page 25).
Once a year
or every
1000 hours
Clean the oil filter.
Check the diesel oil supply lines.
The following must be carried out by a HATZ authorised retailer or
Dometic skilled personnel:
Check the fuel injection pump.
Check the vibration damper.
CAUTION!
Note the following for all maintenance work:
The generator must not be running.
All the parts must be cooled down.