PACKAGED AIR TO AIR ROOFTOP UNITS
WITH SCROLL COMPRESSORS
rtr-rtp-GB•rel.1.3
MP Oversized microprocessor: compared to the standard micro-
processor, it allows a multi-language display reading, a more de-
tailed description of parameters, the possibility to manage up to 8
units, to manage non standard communication protocols, a better
access to the program, to manage free-cooling units (already in-
cluded in the units with option F).
MS Motorized dampers: motor controlled by an external 0-10V sig-
nal, if not dierently specied, when the standard version foresees
manual dampers (already included in the units with option F).
MTB Heating section with gas red burner: additional in-built sec-
tion, where one or more heating module of forced draft type are
installed, each made of a gas red burner and an air/smokes steel
exchanger. This module will heat the air to be introduced in the am-
bient, allowing the air to lick the external surface of the rebox and
the pipes of the exchanger. For the heat pump version this module
can be used as an additional heating section or, for an only cooling
unit, as an alternative to the heat pump itself. This section is realized
in conformity with the regulations in force.
MTC Heating section with boiler: additional in-built section, where
one or more boilers of watertight condensing type are installed,
producing hot water necessary to supply, through a close circuit,
a heating coil. The water circuit is complete with circulator, non re-
turn and check valves. This section is realized in conformity with the
regulations in force.
PA Rubber-type vibration dampers: bell-shaped vibration damp-
ers supports for insulating the unit (supplied in kit), made of base
and bell in galvanized steel and natural rubber mixture.
PM Spring-type vibration dampers: spring-type vibration dampers
support, for insulating the unit (supplied in kit), mainly indicated
for installation in dicult and aggressive environments. Made of
two steel plates containing a suitable quantity of harmonic steel
springs.
PQ Remote microprocessor: remote terminal, allowing to display the
temperature and humidity values detected by probes, the alarm
digital inputs, the outputs and the remote ON/OFF of the unit, to
change and program of the parameters, the sound signal and the
display of the present alarms.
RC Cross-ow heat recovery: cross-ow static heat exchanger with
aluminium plates, installed in a suitable section of the unit, so
to partially allow the transfer to the fresh air of the heating load
present in the exhaust air, increasing the energy eciency of the
unit. The exchanger has no moving components and therefore
there is no energy consumption: the two air ows involved are her-
metically divided and therefore there is no possibility of mixing. The
condensing water is collected in drain pans in stainless steel and
externally discharged. A by-pass damper is positioned side by side
to the heat recovery. On demand, the heat recovery section can
be realized in the 5 dampers version (please get in touch with our
Sales Dept.)
RE Electrical post-heating coil: electrical heaters of candle type with
carbon steel ns, placed after the evaporating coil; the electrical
heaters are used to re-adjust the air temperature to the requested
value, when the evaporator is used to lower the relative humidity in
the ambient. The coil is supplied by the electrical board of the units
and it is controlled by the microprocessor on a several step basis.
VS Solenoid valve: electro-valve for the liquid refrigerant at the com-
pressor’s stop.