Dometic TEC 60 [24/240] Connecting the generator

Dometic TEC 60 [24/240] Connecting the generator
EN
Connecting the electrical power to the generator TEC60, TEC60LPG
24
10.2 Connecting the generator
A
Connect the generator according to the circuit diagrams (fig. g, page 9 and
fig. h, page 10).
The inverter must be supplied by the battery.
Connect positive and negative pole of the battery to the inverter battery
connector (see fig. g 6, page 9).
Legend for circuit diagram in fig. g, page 9
NOTICE!
Connect a relay or a switch to the vehicle’s electrical system (see
chapter “Accessories” on page 18) so that the generator is not
damaged when the power supply is switched on.
Connect the generator so that it takes priority over the power supply.
Item Description
1 Inverter terminals
2 Battery positive terminal
3 Battery negative terminal
4 Generator connector
5 Output connector
6 Battery connector
7 Control panel connector
TEC60-TEC60LPG-I-16s.book Seite 24 Freitag, 15. Juli 2016 8:14 20