Ebara AGA 2.00 M [4/36] Introduction

Ebara AGC 1.50 T [4/36] Introduction
4
GB
OPERATING AND MAINTENANCE MANUAL PART 2
THE USER SHOULD KEEP THIS DOCUMENT
1. INTRODUCTION
This instruction manual is split into two booklets: PART 1,
containing general information regarding our whole product
range; and PART 2, containing information speci c to the
motor-driven pump you have purchased. The two publica-
tions are complementary to each other, so make sure you
have both.
Comply with the instructions contained in them to get the
most out of your motor-driven pump and assure its proper
operation. If you need further information, get in touch with
your nearest authorized dealer.
If information in the two parts contradict each other, take
PART 2 containing the product’s speci c information as
valid.
NO PART OF THESE ILLUSTRATIONS AND/OR TEXT MAY BE
REPRODUCED FOR ANY REASON.
The following symbols have been used in the compilation of this
instruction booklet:
WARNING
Risk of damaging the pump or system
Risk of causing injury or damaging property
Electrical hazard
2. CONTENTS
1. INTRODUCTION page 4
2. CONTENTS page 4
3. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP page 4
4. SPECIFICATIONS page 4
5. PREPARING FOR USE page 4
6. DIAGRAMS AND DRAWINGS page 5
3.
DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP
3.1. DESCRIPTION
Description: MOTOR-DRIVEN SURFACE PUMP
Type: SELF-PRIMING
Model: JESX, JEX, JES, JE, AGA, AGC, AGE, AGF
3.2. USE FOR WHICH PUMPS ARE DESIGNED
Domestic water boosting, small-scale garden watering, handling
from tanks, wells etc., vehicle washing, small pressure vessels
featuring automatic operation, treatment of clean water in gen-
eral (handling of drinking water JES, JE).
Only the GARDEN versions, conforming to EC Directive 2000/14
(noise emission in the environment by equipment for use out-
doors) are designed for portable use outdoors.
Use the motor-driven pumps based on their technical speci-
cations.
3.3. USE FOR WHICH PUMPS ARE NOT DESIGNED
The pumps cannot be used to handle:
dirty water or water with solids in suspension;
water containing acids or bases, and corrosive liquids in
general;
water with a temperature over the temperature limit given in
table 4;
seawater;
ammable liquids and hazardous liquids in general.
The motor-driven pumps must never be made to work without
liquid.
4. SPECIFICATIONS
4.1. JESX, JEX, JES, JE PUMP SPECIFICATIONS
U.M. JES, JE JESX, JEX
Max. temperature
of liquid pumped
°C
35
domestic use according to CE-EN 60335-241
45 other uses 60 other uses
U.M. JE JEX JES JESX
Suction
diameter
* G 1¼ G 1
Delivery
diameter
*G 1
Maximum working
pressure
MPa 0.6
* = threading according to ISO 228
4.2. AGA, AGC, AGE, AGF PUMP SPECIFICATIONS
U.M. AGA (models) AGC AGE AGF
Max. temperature
of liquid pumped
°C 45
Suction diameter *
G 1
(060/075/100)
G 1½ (150/200/300)
G
G 1
Delivery diameter * G 1
Max. working
pressure
MPa
0.6
(060/075/100)
1 (150/200/300)
1 0.6
Max. percentage of
sand drawn in
g/mc 40 -
* = threading according to ISO 228
4.3. MOTOR SPECIFICATIONS
TYPE TEFC
RATINGS See motor-driven pump rating plate
OVERLOAD
PROTECTION
SINGLE PHASE: unless otherwise stated
on the additional sheet, thermal cutout w/
automatic reset.
THREE PHASE: by installer
4.4. INFORMATION ON AIRBORNE NOISE
Pump P2 [kW] Shaft height LpA [dB]*
JES(X) 0.37÷0.60 63 <70
JE(X)
0.60÷0.88
1.1
71
80
71
76
AGE 0.37÷0.60
63 <70
AGF 0.6-0.8
AGA
0.44÷0,75
1.1÷2.2
71
80
71
76
AGC 1.1÷2.2 80 76
The table gives maximum sound emission values for the mo-
tor-driven pumps
* Sound pressure level - Mean value of measurements taken
one metre from the pump. Tolerance ± 2.5 dB.
5. PREPARING FOR USE
WARNING
USE THE HANDLE TO LIFT OR MOVE THE MOTOR-DRIVEN
PUMP, IF IT HAS ONE, OR HOLD IT IN YOUR HANDS: NEVER
USE THE POWER CORD.
libretto_EBARA_386_nuovo.indd 4libretto_EBARA_386_nuovo.indd 4 6-02-2009 10:00:256-02-2009 10:00:25

Содержание