Homa H832 - 45/1,1D [10/12] Months of warranty
![Homa H832 - 45/1,1D [10/12] Months of warranty](/views2/1552039/page10/bga.png)
10
- Ball bearings: Check the shaft for noisy or heavy opera-
tion (turn the shaft by hand). Replace defective ball bear-
ings. A general overhaul of the pump is usally required in
case of defective ball bearings or poor motor function.
This work must be carried out by an authorized
service workshop.
- Cable entry
: Make sure that the cable entry is watertight
and that the cables are not bent sharply and/or pinched.
Additionally at pump types with oil chamber:
- Oil level and oil condition in oil chamber:
Put the pump in horizontal position, so that the screw of
the oil chamber is above (at larger pumps: one of both
screws). Remove the screw and infer a small quantity of
oil. The oil becomes greyish white like milk if it contains
water. This may be the result of defective shaft seal.
In this case leave the condition of the shaft seals by a
HOMA Service to examine.
The oil should be replaced after 3000 operating hours.
Oil type: Shell Tellus C22, degradable HOMA-Atox (avail-
able on request). Used oil is to be disposed accordingly.
Servicing Contract
For a regular expert execution of all necessary mainte-
nance and inspection we recommend the conclusion of a
servicing contract by our HOMA Service. Please contact
our HOMA customer service.
10. Fault Finding Chart
Before maintenance or repair disconnect the pump
from the power supply to avoid accidental starting of the
pump!
Fault Cause Remedy
Motor does not start.
Fuses blow or motor
starter trips out immedi-
ately. Caution: Do not
start again!
• Supply failure; short-
circuit; earth-leakage;
fault in cable or motor
winding
• Have the cable and
motor checked and
repaired by a quali-
fied electrician
• Fuses blow due to use
of wrong type of fuse
• Install fuses of the
correct type
• Impeller blocked by
impurities
• Clean the impeller
• capacitor defective • Check the capacitor
Pump operates, but
motor starter trips out
after a short while
• Low setting of thermal
relay in motor starter
• Set the relay in
accordance with the
specifications on the
pump label
• Increased current
consumption due to
large voltage drop
• Measure the voltage
between two motor
phases. Tolerance:
± 10%
• Impeller blocked by
impurities. Increased
current consumption in
all three phases
• Clean the impeller
Pump operates at
below-standard
• Impeller blocked by
impurities
• Clean the impeller
performance and power
consumption
• •
Oil in the medium
• Wear-out of the radial
shaft ring
• Replace the radial
shaft ring, change
the oil
Pump operates, but
gives no liquid
• Discharge valve
closed or blocked
• Check the discharge
valve and possibly
open and/or clean
• Non-return valve
blocked
• Clean non-return
valve
• •
We grant for the described product in the warranty receipt a
warranty of declared duration in the warranty receipt. The war-
ranty starts with the first start up, latest with the day of sale. A
warranty claim can be raised only by presentation of the fill in
warranty receipt together with the purchase receipt.
Our warranty extends only the removal of material defects or
production defects. Costs for removal and installation of the
complained product at the installation place, costs for the ride of
the mechanicians to the location and from the installation place
as well as costs for transport are not components of our war-
ranty. Complains caused by installation faults or operating faults,
unsuitable operation conditions, deficient care or improper efforts
of repair are out of the question of warranty as well as normal
wear. Hereby arised costs, especially costs for checking and
transport are bearing by the sender or operator of the pump. This
is also valid for an asserted warranty claim if a check results that
the unit works faultless and is free of defects. All products have a
high quality standard. Each product is defeated by a streng
technical end control before delivery. If the unit still gives an
occasion for a legitimated complain, you have the claim of an
appropriated correction free of charge. Warranty repairs only
must lead from the manufacturer or an authorized agency. Trials
of repair by the customer or non-authorized persons during the
warranty, causes an extinguishing of the warranty. A warranty
repair achieved by us does not extend the warranty period. Re-
placed spare parts give no reasons for a new warranty period.
Extensive claims are excluderd, especially such as diminution,
change or compensation also for any kind of follow up damages.
To guarantee a quick transaction of a warranty claim, please
return the product together with the warranty receipt, purchase
receipt and declaration of defect carriage paid to the manufac-
turer (for the adress see warranty receipt).
Claims caused by damages of transport could be only accepted,
if the damage is established or confirmed by delivery in the
presence of the forwarder, parcel service, train or post.
Pump type
No.
Correspond to our warranty conditions
we achieve
12 months of warranty
Warranty Conditions
✂
HOMA Pumpenfabrik GmbH
Industriestraße 1
D-53819 Nk.-Seelscheid
Telefon: + 49 (0) - 22 47 - 70 20
Telefax: + 49 (0) - 22 47 - 7 02 44
Train station: D-53819 Nk.-Seelscheid
Warranty receipt
Содержание
- H 842 h 844 h 846 h 847 h 862 h 863 1
- Hochdruck tauchmotorpumpen deepwell submersible pumps 1
- Montage und bedienungsanleitung installation and operation instruction manual 1
- Inhaltsverzeichnis 2
- Konformitätserklärung 2
- Einsatz und technische beschreibung 3
- Garantie 3
- Sicherheitshinweise 3
- Transport und lagerung 3
- Elektroanschluß 4
- Inbetriebnahme 4
- Montage und installation 4
- Wartung und reparatur 4
- Bei pumpentypen mit ölsperrkammer kann beim lösen der öl kontrollschraube überdruck aus der ölsperrkammer entweichen schraube erst dann völlig herausschrauben wenn druckausgleich erfolgt ist die pumpe sollte bei normalem betrieb mindestens ein mal jährlich überprüft werden bei dauerbetrieb oder besonderen bedingungen z b stark abrasives förder medium sind die wartungen nach jeweils 1 00 be triebsstunden durchzuführen 5
- Das öl sollte nach jeweils 3000 betriebsstunden gewech selt werden ölsorte shell tellus c22 oder biologisch abbaubares homa atox auf wunsch lieferbar ver brauchtes öl ist ordnungsgemäß zu entsorgen 5
- Pumpe horizontal legen so dass sich die ölkammerschraube bei größeren pumpen eine der beiden ölkammerschrauben oben befindet die schraube entfernen und eine geringe menge öl entnehmen wenn das öl trübe oder milchig ist deutet dies auf eine schadhafte wellenabdichtung hin in diesem fall den zustand der wellendichtungen durch eine homa fachwerkstatt oder den werkskundendienst überprüfen lassen 5
- Stromaufnahme a mit meßgerät kontrollieren und mit dem sollwert betriebspunkt oder nennstromangabe auf dem typenschild vergleichen pumpengehäuse und laufrad auf sichtbaren verschleiß prüfen ggf austauschen wellenlager durch drehen der welle auf freien und geräuschlosen lauf prüfen bei schäden ist eine gene ralüberholung durch eine homa fachwerkstatt bzw den werkskundendienst notwendig kabel und kabeleinführung auf wasserdichtheit oder beschädigungen prüfen sichtprüfung zusätzlich bei pumpentypen mit ölsperrkammer 5
- Störungen ursache abhilfe 5
- Suchen beruhen welche nicht vom herstellerwerk oder einer autorisierten fachwerkstatt durchgeführt wurden oder wenn bei einem teileaustausch keine original ersatzteile verwendet wurden nicht haften für zubehörteile gelten die gleichen bestimmungen 5
- Um einen problemlosen betrieb der pumpe langfristig zu erreichen sollten bei wartungen stets zumindest die nachfolgenden überprüfungen vorgenommen werden 5
- Vor beginn der arbeit den stillstand aller rotierenden teile abwarten 5
- Vor beginn der arbeiten die pumpe gründlich mit sauberem wasser reinigen pumpengehäuse auch innen durchspülen bei der zerlegung pumpenteile jeweils mit wasser reinigen 5
- Vor jeder arbeit die pumpe vom elektroanschluss trennen um ein versehentliches einschalten der pumpe während der arbeit zu vermeiden 5
- Vor jeder wartung pumpe vom stromnetz trennen netzstecker ziehen 5
- Wartungsvertrag 5
- Zur regelmäßigen fachmännischen durchführung aller notwendigen wartungs und kontrollarbeiten empfehlen wir den abschluss eines wartungsvertrages durch unseren homa wartungsservice bitte wenden sie sich an unseren werkskundendienst 5
- Ölstand und ölzustand 5
- Für die tauchmotorpumpe nr leisten wir entsprechend unseren garantiebedingungen 6
- Garantiebedingungen 6
- Garantieschein 6
- Homa vertragskundendienste im bundesgebiet 6
- Monate garantie 6
- Contents 7
- Declaration of conformity 7
- Applications and technical description 8
- Electrical connection 8
- Safety warnings 8
- Transport and storage 8
- Warranty 8
- Installation 9
- Maintenance and repair 9
- Start up 9
- Fault finding chart 10
- Months of warranty 10
- Pump type no correspond to our warranty conditions we achieve 10
- Warranty conditions 10
- Warranty receipt 10
Похожие устройства
- Homa H832 - 45/1,1D Технические данные
- Homa H802 W Инструкция по эксплуатации
- Homa H802 W Технические данные
- Homa H804 W Инструкция по эксплуатации
- Homa H804 W Технические данные
- Homa H806 W Инструкция по эксплуатации
- Homa H806 W Технические данные
- Homa H808 W Инструкция по эксплуатации
- Homa H808 W Технические данные
- Homa H812 WA Инструкция по эксплуатации
- Homa H812 WA Технические данные
- Homa H816 WA Инструкция по эксплуатации
- Homa H816 WA Технические данные
- Homa H816 SW Инструкция по эксплуатации
- Homa H816 SW Технические данные
- Homa H818 WA Инструкция по эксплуатации
- Homa H818 WA Технические данные
- Polaris PUH 8105 TF Инструкция по эксплуатации
- Polaris PAW 4204Di Инструкция по эксплуатации
- Polaris PUH 1006Di Инструкция по эксплуатации