Tascam MX Connect [11/26] Compressor tab

Tascam MX Connect [11/26] Compressor tab
TASCAM MX CONNECT
11
2 - TASCAM MX CONNECT
COMPRESSOR tab
When the input volume exceeds the THRESHOLD level, the input
volume is compressed, reducing output volume variation.
For example, by reducing the levels of loud sounds, lower level
sounds become relatively louder, creating a more even volume
level throughout and a more sustained sound.
1 Compressor ON/OFF button
Use this to turn the compressor on/off.
The button lights when on.
2 Compressor status
Three meters show the compressor input signal level, output
signal level and gain reduction level (GR).
NOTE
The graph appears blue when the compressor is on and gray
when it is off.
3 THRESHOLD
Sets the threshold level that will cause the compressor to start.
Tap this to open a setting value list.
Range: -32 dB – 0 dB (default: 0 dB)
4 RATIO
Sets the compression ratio for the input volume.
Raising the value raises the compression ratio, increasing the
amount of compression.
Tap this to open a setting value list.
Range: 1.0:1 – ∞:1 (default: 1.0:1)
5 GAIN
Sets the gain of the output signal.
When the volume is compressed, the output level becomes
lower than the input level.
By using this to amplify the output signal, the level can be
restored to close to the input level.
Tap this to open a setting value list.
Range: 0 dB – 20 dB (default: 0 dB)
6 ATTACK
This sets the time until the compression reaches the RATIO
setting after the input volume exceeds the threshold.
Range: 2 ms – 200 ms (default: 2 ms)
To set the time, use the slider, keyboard input in the set time
field, or the
g
and
t
buttons.
7 RELEASE
Sets the amount of time until the compression stops and the
sound returns to its uncompressed level after the input sound
goes below the threshold level.
Range: 10 ms – 1000 ms (default: 10 ms)
To set the time, use the slider, keyboard input in the set time
field, or the
g
and
t
buttons.

Содержание

Скачать