ABB ASL09-30-10S-81 [41/202] Time time time

ABB ASL09-30-10-81 [41/202] Time time time
ABB Motor protection and control - short form catalog | 3/3
Screw terminals Soldering pins Flat pins
AC Control supply
3-pole contactors
Coil consumption 3.5 W
Type
B6 B7
- -
B6...P B7...P
- -
B6...F B7...F
- -
3-pole reversing contactors
Coil consumption 3.5 W
Type
- -
VB6
VB6A
2)
VB7
VB7A
2)
- -
VB6...P
VB6A...P
2)
VB7...P
VB7A...P
2)
- -
VB6...F
VB6A...F
2)
VB7...F
VB7A...F
2)
4-pole contactors
Coil consumption 3.5 W
Type
B6 B7
- - - - - - - -
DC Control supply
3-pole contactors
Coil consumption 3.5 W
Type
BC6 BC7
B7D
1)
- -
BC6...P BC7...P
B7D...P
1)
- -
BC6...F BC7...F
B7D...F
1)
- -
3-pole interface contactors
Coil consumption 1.4 ... 2.4 W
Type
BC6 BC7
- -
BC6...P BC7...P
- -
BC6...F BC7...F
- -
3-pole reversing contactors
Coil consumption 3.5 W
Type
- -
VBC6
VBC6A
2)
VBC7
VBC7A
2)
- -
VBC6...P
VBC6A...P
2)
VBC7...P
VBC7A...P
2)
- -
VBC6...F
VBC6A...F
2)
VBC7...F
VBC7A...F
2)
4-pole contactors
Coil consumption 3.5 W
Type
BC6 B7D
- - - -
Wide range types
Extended coil voltage and
temperature
Type
-
TBC7
PLC types
Coil consumption 1.7 W
Type
B6S
1)
B7S
1)
IEC
Rated operational power AC-3
220-230-240 V kW 2.2 3 2.2 3 2.2 3 2.2 3 2.2 3 2.2 3
380-400 V kW 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5 4 5.5
Rated operational current AC-1
400 V, θ ≤ 40 °C A 20 20 20 20 12 12 12 12 20 20 20 20
UL/
CSA
3-phase motor rating 220-240 V AC hp 2 3 2 3 2 3 2 3 2 3 2 3
440-480 V AC hp 3 5 3 5 3 5 3 5 3 5 3 5
General use rating A 12 (300 V) 16 (600 V) 12 (300 V) 16 (600 V) 12 (300 V) 16 (600 V) 12 (300 V) 16 (600 V) 12 (300 V) 16 (600 V) 12 (300 V) 16 (600 V)
1)
With integrated surge suppressor
2)
With safety blocking function
Main accessories
Auxiliary contact blocks Front mounting CAF6 - -
Side mounting CA6 CA6-11K-P CA6-11K-F
Connection sets For reversing contactors BSM6-30 - -
Surge suppressors Varistor (AC/DC) RV-BC6 - -
Overload relays
Thermal overload relays
Thermal and phase failure protection, with single setup possible
Class 10
T16 - -
Electronic overload relays
With single setup possible
Class 10E, 20E, 30E
E16DU - -
Manual motor starters
Thermal / magnetic protection
Class 10
MS116, MS132 MS116, MS132 MS116, MS132
Magnetic only types MO132 MO132 MO132
Connecting link to manual motor starters BEA7/132 - -
Screw terminals Soldering pins Flat pins
AC Control supply
4-pole contactor relays
Coil consumption 3.5 W
Type
K6 K6...P K6...F
DC Control supply
4-pole contactor relays
Coil consumption 3.5 W
Type
KC6 KC6...P KC6...F
4-pole interface contactor relays
Coil consumption
1.4 ... 2.4 W
Type
KC6 KC6...P KC6...F
Wide range types
Extended coil voltage and
temperature
Type
TKC6
IEC
Rated operational current
AC-15
220-230-240 V A 4 4 4
380-400 V A 3 3 3
Rated operational current
DC-13
24 V A 2.5 2.5 2.5
Main accessories
Auxiliary contact blocks Front mounting CAF6 - -
Side mounting CA6-11K CA6-11K-P CA6-11K-F
2CDC102050C0201
3
ABB Motor protection and control - short form catalog | 3/3
Time) Time) Time)

Содержание

Скачать