ABB ACS550-01-08A8-4+B055 [4/5] Replacement
![ABB ACS550-01-072A-4 [4/5] Replacement](/views2/1556842/page4/bg4.png)
ABB Drives
CAPACITOR REFORMING
Inspection Instruction
3AFE 6873 5190
00522808_G.DOC
Dept.
Project
ORANGE
Status Date
05.May 2010
Author
Haapala Mari
Status
APPROVED/DAVIDSAINEN JANNE
Revision
G
Page
4 / 5
Capacitor reforming is based on DC power supply, which is connected to the drive input.
The power supply current charges drive capacitors. If the power supply cannot limit the
current, the voltage is increased gradually (with e.g. 100V steps). The maximum
recommended reforming current is 100mA. An appropriate reforming voltage is (1.35 ...
2) * U
x
. See the reforming time in figure 1.
WARNING: Disconnect the mains supply while the reforming circuit is connected.
Note! Markings for drive input differs between drive types:
ACS550
U1 V1 W1
ACS150/310/320/350/355
U1/L V1/N W1
ACS50/55
L/R N/S
Figure 3. The reforming circuit for method 2B.
2 Replacement
The drive intermediate circuit employs several electrolytic capacitors. Capacitor life can
be prolonged by lowering the ambient temperature.
It is not possible to predict a capacitor failure. Capacitor failure is usually followed by an
input power fuse failure or a fault trip. Contact ABB if capacitor failure is suspected.
Replacements for ACS550 frame sizes R5 and R6 are available from ABB. Do not use
other than ABB specified spare parts.
Содержание
- Abb drives 1
- Capacitor reforming 1
- Guide for capacitor reforming in acs50 acs55 acs150 acs310 acs350 acs355 acs550 ach550 and r1 r4 oint sint boards 1
- How to check the drive s age 1
- Inspection instruction 3afe 6873 5190 1
- Reforming 1
- Abb drives 2
- Capacitor reforming 2
- Drives stocked non operational for 2 years and over 2
- Drives stocked non operational for less than 2 years 2
- Inspection instruction 3afe 6873 5190 2
- Reforming time 2
- A method 2a 3
- Abb drives 3
- B method 2b 3
- Capacitor reforming 3
- Inspection instruction 3afe 6873 5190 3
- Abb drives 4
- Capacitor reforming 4
- Inspection instruction 3afe 6873 5190 4
- Replacement 4
- Abb drives 5
- Capacitor reforming 5
- Inspection instruction 3afe 6873 5190 5
- Reforming instructions for r1 r4 oint and sint boards 5
Похожие устройства
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Брошюра
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Ввод в эксплуатацию
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Входные фильтры для Micro Drive
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Инструкция по программированию
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Инструкция по эксплуатации
- Danfoss Micro Drive FC-051P1K75 0.75кВт, 4.2А, 220В Руководство по проектированию
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Брошюра
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Ввод в эксплуатацию
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Входные фильтры для Micro Drive
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Инструкция по программированию
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Инструкция по эксплуатации
- Danfoss Micro Drive FC-051P1K5 1.5кВт, 6.8А, 220В Руководство по проектированию
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Брошюра
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Ввод в эксплуатацию
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Входные фильтры для Micro Drive
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Инструкция по программированию
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Инструкция по эксплуатации
- Danfoss Micro Drive FC-051P2K2 2.2кВт, 9.6А, 220В Руководство по проектированию
- Danfoss Micro Drive FC-051P3K0 3кВт, 7.2А, 380В Брошюра
- Danfoss Micro Drive FC-051P3K0 3кВт, 7.2А, 380В Ввод в эксплуатацию