4.1.17 16-** Data Read-outs
Par.
No.
#
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
16-0* General Status
16-00 Control Word 0 N/A 1 set-up TRUE 0 Uint16
16-01 Reference [Unit] 0 ReferenceFeedbackUnit 1 set-up TRUE -3 Int32
16-02 Reference [%] 0 % 1 set-up TRUE -1 Int16
16-03 Status Word 0 N/A 1 set-up TRUE 0 Uint16
16-05 Main Actual Value [%] 0 % 1 set-up TRUE -2 Int16
16-09 Custom Readout 0 CustomReadoutUnit 1 set-up TRUE -2 Int32
16-1* Motor Status
16-10 Power [kW] 0 kW 1 set-up TRUE -3 Uint32
16-11 Power [hp] 0 hp 1 set-up TRUE -3 Uint32
16-12 Motor Voltage 0 V 1 set-up TRUE -1 Uint32
16-13 Frequency 0 Hz 1 set-up TRUE -1 Uint32
16-14 Motor current 0 A 1 set-up TRUE -2 Uint16
16-15 Frequency [%] 0 % 1 set-up TRUE -1 Uint16
16-18 Motor Thermal 0 % 1 set-up TRUE 0 Uint8
16-3* Drive Status
16-30 DC Link Voltage 0 V 1 set-up TRUE 0 Uint32
16-33 Brake Energy /2 min 0 kW All set-ups FALSE 0 Uint32
16-34 Heatsink Temp. 0 °C 1 set-up TRUE 100 Int8
16-35 Inverter Thermal 0 % 1 set-up TRUE 0 Uint8
16-36 Inv. Nom. Current 0 A 1 set-up TRUE -2 Uint16
16-37 Inv. Max. Current 0 A 1 set-up TRUE -2 Uint16
16-38 SL Controller State 0 N/A 1 set-up TRUE 0 Uint8
16-39 Control Card Temp. 0 °C All set-ups FALSE 100 Uint16
16-5* Ref. & Feedb.
16-50 External Reference 0 % 1 set-up TRUE -1 Int16
16-52 Feedback[Unit] 0 ProcessCtrlUnit 1 set-up TRUE -3 Int32
16-57 Feedback [RPM] 0 RPM All set-ups FALSE 67 Int32
16-6* Inputs & Outputs
16-60 Digital Input 0 N/A 1 set-up TRUE 0 Uint16
16-61 Terminal 53 Setting ExpressionLimit 1 set-up TRUE - Uint8
16-62 Analog Input 53 1 N/A 1 set-up TRUE -2 Uint16
16-63 Terminal 54 Setting ExpressionLimit 1 set-up TRUE - Uint8
16-64 Analog Input AI54 1 N/A 1 set-up TRUE -2 Uint16
16-65 Analog Output 42 [mA] 0 mA 1 set-up TRUE -2 Uint16
16-66 Digital Output 0 N/A 1 set-up TRUE 0
VisStr[5
]
16-67 Pulse Input 29[Hz] 0 N/A All set-ups FALSE 0 Int32
16-68 Pulse Input 33 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-69 Pulse Output 27 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-70 Pulse Output 29 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-71 Relay Output 0 N/A 1 set-up TRUE 0 Uint16
16-72 Counter A 0 N/A 1 set-up TRUE 0 Int16
16-73 Counter B 0 N/A 1 set-up TRUE 0 Int16
16-79 Analog Output AO45 0 mA 1 set-up TRUE -2 Uint16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1 0 N/A 1 set-up TRUE 0 Uint16
16-82 Fieldbus REF 1 0 N/A 1 set-up TRUE 0 Int16
16-84 Comm. Option STW 0 N/A 1 set-up TRUE 0 Uint16
16-85 FC Port CTW 1 1084 N/A 1 set-up FALSE 0 uint16
16-86 FC Port REF 1 0 N/A 1 set-up TRUE 0 Int16
16-9* Diagnosis Readouts
16-90 Alarm Word 0 N/A 1 set-up TRUE 0 Uint32
16-91 Alarm Word 2 0 N/A 1 set-up TRUE 0 Uint32
16-92 Warning Word 0 N/A 1 set-up TRUE 0 Uint32
16-93 Warning Word 2 0 N/A 1 set-up TRUE 0 Uint32
16-94 Ext. Status Word 0 N/A 1 set-up TRUE 0 Uint32
16-95 Ext. Status Word 2 0 N/A 1 set-up TRUE 0 Uint32