Emotron FLD48-250-54 [6/20] Emotron flowdrive ip20 version
![Emotron FLD48-045-20 [6/20] Emotron flowdrive ip20 version](/views2/1574009/page6/bg6.png)
6
www.emotron.com
Emotron FlowDrive - IP20 version
Typical motor power at mains voltage 230V, 400V and 460V.
Model
Max. output
current
[A]*
Normal duty
(120%, 1 min every 10 min)
Frame
size
Rated current
[A]
Power @ 230V
[kW]
Power @230V
[hp]
Power @ 400V
[kW]
Power @460V
[hp]
FLD48-2P5-2Y
3.0 2.5 0.37 0.5 0.75 1
A3
FLD48-3P4-2Y 4.1 3.4 0.55 0.75 1.1 1.5
FLD48-4P1-2Y 4.9 4.1 0.75 1 1.5 2
FLD48-5P6-2Y 6.7 5.6 1.1 1.5 2.2 3
FLD48-7P2-2Y 8.6 7.2 1.1 1.5 3.0 4
FLD48-9P5-2Y 11.4 9.5 2.2 3 4.0 5
FLD48-012-2Y 14.4 12. 2.2 3 5.5 7.5
FLD48-016-2Y 19.2 16 4.0 5.5 7.5 10
B3
FLD48-023-2Y 27.6 23 5.5 7.5 11 15
FLD48-032-2Y 37.2 31 7.5 10 15 20
C3
FLD48-038-2Y 45.6 38 11 15 18.5 25
FLD48-025-20 30 25 5.5 7.5 11 15
C2
FLD48-030-20 36 30 7.5 10 15 20
FLD48-036-20 43 36 7.5 10 18.5 25
FLD48-045-20 54 45 11 15 22 30
FLD48-058-20 72 58 15 20 30 40
FLD48-072-20 86 72 18.5 25 37 50
D2
FLD48-088-20 106 88 22 30 45 60
FLD48-105-20 127 106 30 40 55 75
FLD48-142-20 170 142 37 50 75 100
E2
FLD48-171-20 205 171 45 60 90 125
FLD48-205-20 246 205 55 75 110 150
F2FLD48-244-20 293 244 75 100 132 200
FLD48-293-20 352 293 90 125 160 250
* Available for a limited time and as long as drive temperature permits. Rated data at 40 °C ambient temperature.
Содержание
- Technical catalogue emotron flowdrive 1
- Contents 2
- Dedicated waste water drive 2
- Emotorn flowdrive page 3 specifications page 7 2
- General information overview for emotron flowdrive 2
- Speed control offers great energy and maintenance savings emotron ac drives ensure high efficiency and reliability whether your need is to adapt a pump s operation to variations in flow our ac drives emotron flowdrive are available in sizes 0 5 3000 kw 230 690v and with protection class ip20 ip21 and ip54 2
- Standard options page 13 2
- Emotron flowdrive dedicated waste water drive 3
- Emotron flowdrive ip54 version 4
- Typical motor power at mains voltage 230v 400v and 460v 4
- Emotron flowdrive ip54 version 5
- Typical motor power at mains voltage 525v 575v and 690v 5
- Emotron flowdrive ip20 version 6
- Typical motor power at mains voltage 230v 400v and 460v 6
- Coated boards 3c 7
- Environmental conditions 7
- General specifications 7
- General specifications for emotron flowdrive 7
- Dimensions weights and cooling air flow 8
- Operation at higher temperatures 8
- Possible derating 8
- Standards 8
- Ip2y and ip20 21 version of emotron flowdrive 9
- Mechanical specifications for model flowdrive ip2y and ip20 21 version 9
- Mechanical specifications for models fld48 fld52 fld69 ip54 version 10
- Basic i o data 11
- User interface data 12
- All boards are coated support for 2 option boards and one communication option 13
- All boards are uncoated available as coated on request support for 3 option boards and one communication option 13
- Frame sizes a3 c3 frame sizes c2 f2 and b f 13
- Ip2y ip20 21 and ip54 13
- Isolated rs232 rs485 serial communication board for modbus rtu communication protocol baud rates 2400 38400 bits s supported 13
- Part no remark part no remark 13
- Ptc isolated input conforming din 44081 44082 max 6 ptc thermistors can be connected in series to ptc input also including 3 pt100 inputs 2 3 4 wire conforming en 60751 13
- Ptc isolated input conforming din 44081 44082 max 6 ptc thermistors can be connected in series to ptc input rtc real time clock function for flowdrive makes it possible to start functions at desired date time or weekday 13
- Ptc pt100 board 13
- Ptc rtc board 13
- Rs232 rs485 isolated 13
- Rtc board 13
- Rtc real time clock function for flowdrive makes it possible to start functions at desired date time or weekday 13
- Standard option 13
- Standard options 13
- Standard options for emotron flowdrive 13
- Control panel kit incl blank panel 14
- Control panel kit incl control panel 14
- Ethernet etherca 14
- Ethernet ethernet ip 2 port 14
- Ethernet modbus tcp 14
- Ethernet modbus tcp m12 14
- Ethernet profinet io 1 port 14
- Ethernet profinet io 2 port 14
- Fieldbus and ethernet boards 14
- Fieldbus devicenet 14
- Fieldbus profibus 14
- Safe stop 14
- Standard options for emotron flowdrive 14
- Standby power supply 14
- Blank control panel 15
- Dc dc connection 15
- Emc filter class c2 15
- Emosoftcom 15
- Factory mounted options for emotron flowdrive 15
- Glands for ip54 frame sizes b c and d 15
- Safe stop 15
- Standard options for emotron flowdrive 15
- Standby power supply 15
- Extended emc filter 90 300a 16
- Extended options for emotron flowdrive 16
- Output choke du dt 16
- Overshoot clamp 16
- Common mode filter 17
- Liquid cooling 17
- Sine wave filter 17
- Cad drawings available on the web 18
- Filter selection guide 18
- Emotron services 20
- Service and support secure the value of your investment 20
- Technical centres 20
Похожие устройства
- Emotron FLD48-250-54 Руководство по эксплуатации
- Emotron CDU/CDX 48-008 Руководство по эксплуатации
- Emotron CDU/CDX 48-008 Спецификация
- Emotron CDU/CDX 48-010 Руководство по эксплуатации
- Emotron CDU/CDX 48-010 Спецификация
- Emotron CDU/CDX 48-013 Руководство по эксплуатации
- Emotron CDU/CDX 48-013 Спецификация
- Emotron CDU/CDX 48-018 Руководство по эксплуатации
- Emotron CDU/CDX 48-018 Спецификация
- Emotron CDU/CDX 48-026 Руководство по эксплуатации
- Emotron CDU/CDX 48-026 Спецификация
- Emotron CDU/CDX 48-031 Руководство по эксплуатации
- Emotron CDU/CDX 48-031 Спецификация
- Emotron CDU/CDX 48-037 Руководство по эксплуатации
- Emotron CDU/CDX 48-037 Спецификация
- Emotron CDU/CDX 48-046 Руководство по эксплуатации
- Emotron CDU/CDX 48-046 Спецификация
- Emotron VS30-23-1P7-20 Инструкция по эксплуатации
- Emotron VS30-23-1P7-20 Каталог
- Emotron VS30-23-2P4-20 Инструкция по эксплуатации