Galletti AREO 23 4р [2/12] Areo s
![Galletti AREO 62 S [2/12] Areo s](/views2/1577872/page2/bg2.png)
2
AP66000271 - 01
All copying, even partial, of this manual is strictly forbidden
AREO S
2 CONSTRUCTIVE FEATURES
Gli aerotermi per funzionamento a vapore sono principalmente costituiti dai
componenti elencati di seguito.
> Prepainted sheet steel cabinet complete with heat-proof ABS corner
trim. The cabinet is complete with adjustable aluminium louvers
(spring operated) placed on the air outlet which allow an optimal
distribution of the air within the heated room. They are supplied with
brackets for suspending the fan heater to the ceiling or joining it to
the mounting board for installation on the wall (accessory).
> High conductivity heat exchanger made with copper tubes and
aluminium fins assuring higher heat exchange than standard iron
tubes exchangers. All circuit are in parallel without siphons to drain
perfectly the condensed steam.
> All motors are standard equipped with:
- internal thermal protection (klixon)
- windings in class F
- protection degree IP55.
- Two speeds, 4/6 poles or 6/8 poles, in the 400 / 3 / 50
version, delta-star type.
> Axial fan with statically balanced sickle blades housed in a
specially designed compartment that enhances ventilation and
reduces noise emissions.
> Safety grille made of electrogalvanised steel wire: it supports the
motor and is fixed to the cabinet by means of vibration damping
supports.
3 AVAILABLE OPTIONS
CST Delta/star selector for installation in electric panels
CSTP Delta/star selector with box for wall installation
TA Electromechanical room thermostat
TA2 Wall mounted room thermostat with summer-winter selector
DFP Wall mounting board
DFC Column mounting board
DFO Adjustable wall/column mounting board
PAE Fresh air intake louver
GR Fresh air intake grille
DO Additional row of louvers
R Protection grill for gymnasium (against ball impact)
(1) Cabinet: side panel
(2) Cabinet: upper panel
(3) Cabinet: lower panel
(4) Rear panel/fan compartment
(5) Safety grille (fan) supporting motor
(6) Finned block heat exchanger (heat exchanger coil)
(7) Adjustable louvers
(8) Conveyor duct
(9) Plastic corner trim on cabinet (left and right)
(10) Wall/ceiling mounting brackets
1 UNIT DESCRIPTION
INDEX
1 UNIT DESCRIPTION ......................................................................... 2
2 CONSTRUCTIVE FEATURES ............................................................. 2
3 AVAILABLE OPTIONS ....................................................................... 2
4 RATED TECHNICAL DATA .................................................................. 3
5 SOUND LEVELS ............................................................................... 3
6 HEATING CAPACITY ....................................................................... 4 - 6
7 HEIGHT OF INSTALLATION -
WALL MOUNTING ........................................................................... 7
8 HEIGHT OF INSTALLATION
CEILING MOUNTING ........................................................................ 7
9 OVERALL DIMENSIONS ................................................................... 8
10 ELECTRICAL DATA ............................................................................ 9
11 WIRING DIAGRAMS ........................................................................ 9
12 ACCESSORIES ................................................................................ 10
OPERATING LIMITS
- thermal carrier fluid
- max steam pressure: 10 bar
- max steam temperature: 180°C
- Air inlet temperature: -10°C to +40°C
- Power supply: rated voltage +/- 10%
DECLARATION OF CONFORMITY
Galletti S.p.A. whose main office is located at 12/a via Romagnoli,
40010 Bentivoglio (BO) - Italy, hereby declares, under its own
responsibility, that the fan heaters belonging to the AREO S series,
indoor units for air-conditioning systems, conform to the
specifications of EEC Directives 73/23, 89/392, 91/368, /93/44, 93/
68, 89/336, 83/97 and subsequent modifications.
Bologna 30/06/2004 Luigi Galletti
President
1
1
2
3
4
5
6
7
8
10
9
Содержание
- Areo s 2
- Available options 2
- Constructive features 2
- Declaration of conformity 2
- Operating limits 2
- Unit description 2
- A weighted sound power level vr fan speed 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm 8 p 8 poles 700 rpm 3
- A weighted sound pressure level 5m distance 2 directional factor lw octave band sound power level l 3
- Ap66000271 01 3
- Areo s 3
- Legend 3
- Rated capacity determined at the following conditions heating mode steam pressure 1 bar 120 c inlet air temperature 20 c sound pressure distance of 5 meters directional factor equal to 2 fan speed 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm 8 p 8 poles 700 rpm 3
- Rated technical data 3
- Sound levels 3
- The technical and dimensional data reported in this manual may be modified in view of any product improvement 3
- Ap66000271 01 4
- Areo s 4
- Heating capacity 4
- Inlet air temperature ts steam temperature vr fan speed 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm 4
- Legend ps steam pressure pt heating capacity qa air flow qs steam flow rate tb 4
- Outlet air temperature tb 4
- Ap66000271 01 5
- Areo s 5
- Heating capacity 5
- Inlet air temperature ts steam temperature vr fan speed 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm 5
- Legend ps steam pressure pt heating capacity qa air flow qs steam flow rate tb 5
- Outlet air temperature tb 5
- Ap66000271 01 6
- Areo s 6
- Heating capacity 6
- Inlet air temperature ts steam temperature vr fan speed 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm 6
- Legend ps steam pressure pt heating capacity qa air flow qs steam flow rate tb 6
- Outlet air temperature tb 6
- Areo s 7
- Height of installation ceiling mounting 7
- Height of installation wall mounting 7
- Legend 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm ho maximum installation height ao floor influence area bo floor influence area 7
- Legend 4 p 4 poles 1400 rpm 6 p 6 poles 900 rpm hv maximum installation height ao throw distance bo floor influence area 7
- Areo s 8
- Areo s basic version 8
- Gr outdoor air intake grille 8
- Overall dimensions 8
- Pae fresh air intake 8
- Ap66000271 01 9
- Areo s 9
- Cst star triangle switch m motor 9
- Delta connection to terminal block of 400 400 v y motors high speed 9
- Electrical data 9
- Features of the standard motor tropicalised equipped internally with a thermal cutout ip 55 protection degree class f winding closed type asynchronous three phase 2 speed motors 400 400 v star delta connection 400 400 v y motors are equipped internally with a thermal cutout and speeds are selected by means of a normal star delta switch accessory cst the terminals of the cutouts are connected to the terminal block so that they can be used as protection in series with the coil of a contactor if the internal cutout is not used to protect the motor it will be necessary to provide a motor overload cutout set at a current that is 10 15 higher than the current indicated on the unit rating plate 9
- Make the electrical connections with the power supply disconnected in accordance with current safety regulations all the wiring must be done by qualified personnel check that the mains electricity supply is compatible with the voltage shown on the unit rating plate scrupulously follow the wiring diagram provided according to the type of installation each unit requires a switch il on the feeder line with a distance of at least 3 mm between the opening contacts and a suitable safety fuse f 9
- Selector y 9
- Star connection to terminal block of 400 400 v y motors low speed 9
- Wiring diagram showing connection of 400 400 v motor with star delta 9
- Wiring diagrams 9
- Accessories 10
- Areo s 10
- Areo s 11
Похожие устройства
- Galletti AREO 24 4р Инструкция по эксплуатации
- Galletti AREO 22 6р Инструкция по эксплуатации
- Galletti AREO 23 6р Инструкция по эксплуатации
- Galletti AREO 24 6р Инструкция по эксплуатации
- Galletti AREO 22 8р Инструкция по эксплуатации
- Galletti AREO 23 8р Инструкция по эксплуатации
- Galletti AREO 24 8р Инструкция по эксплуатации
- Galletti AREO 32 4р Инструкция по эксплуатации
- Galletti AREO 33 4р Инструкция по эксплуатации
- Galletti AREO 34 4р Инструкция по эксплуатации
- Galletti AREO 32 6р Инструкция по эксплуатации
- Galletti AREO 33 6р Инструкция по эксплуатации
- Galletti AREO 34 6р Инструкция по эксплуатации
- Galletti AREO 32 8р Инструкция по эксплуатации
- Galletti AREO 33 8р Инструкция по эксплуатации
- Galletti AREO 34 8р Инструкция по эксплуатации
- Galletti AREO 42 4р Инструкция по эксплуатации
- Galletti AREO 43 4р Инструкция по эксплуатации
- Galletti AREO 44 4р Инструкция по эксплуатации
- Galletti AREO 42 6р Инструкция по эксплуатации