KSB Filtra 22 D [14/36] Noise characteristics

KSB Filtra 18 D [14/36] Noise characteristics
4 Description of the Pump (Set)
14 of 36
Filtra N
Function The fluid enters the pump via a suction nozzle (2) and is accelerated outwards by the
rotating impeller (7). In the flow passage of the pump casing the kinetic energy of
the fluid is converted into pressure energy. The fluid is pumped to the discharge
nozzle (1), where it leaves the pump. At the rear side of the impeller, the shaft (3)
enters the casing via the casing wall. The shaft passage through the cover is sealed
towards the atmosphere with a shaft seal (4). The shaft runs in a rolling element
bearing.
Sealing The pump is sealed by a mechanical seal with rotating torque-transmitting elements.
4.6 Noise characteristics
Table4: Surface sound pressure level L
wA
Size Noise characteristic
[dB]
6E 69
8E 70
12E 75
14E 72
18E 74
22E 78
24E 80
6D- 8D 69
12D 75
14D 71
18D 77
22D 78
24D 79
30D 80
4.7 Scope of supply
Depending on the model, the following items are included in the scope of supply:
Pump set
Accessories
Further required accessories can be purchased from our distributors.