Filtra N
5 Installation at Site
5.1 Safety regulations
DANGER
Unsuitable electrical installation
Danger to life!
Make sure the electrical installation meets the VDE 0100 installation rules (i.e.
sockets with earthing terminals).
Make sure the electric mains is equipped with a residual current device of
maximum 30 mA.
Always have the electrical connections installed by a trained and qualified
electrician.
DANGER
Use in an outdoor area
Danger of death from electric shock!
Install the pump to IEC 364-7-702 / NFC 15.100 Section 702 at least 3 metres
away from the edge of the pool in a location which is protected against
flooding, or in an adjacent room which can be entered via a lockable door or
trapdoor.
Provide connections between pump and swimming pool which are insulated,
e.g. with PVC, or run in metal pipes which are linked with the common earthing
conductor of the swimming pool.
Ensure correct installation of the seal element in the terminal box.
DANGER
Damaged cables and plugs
Danger of death from electric shock!
Check the cables and power cables for damage before connecting them.
Never connect damaged power cables or damaged plugs.
DANGER
Damaged terminal box
Danger of death from electric shock!
Never operate a pump with a damaged terminal box.
5.2 Checks to be carried out prior to installation
Before beginning with the installation check the following:
The pump set can be operated on the power supply network according to the
data on the name plate.
The fluid to be handled matches the description of suitable fluids.