6 Commissioning/Start-up/Shutdown
21 of 36
Filtra N
6.3 Shutdown/storage/preservation
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
Always have the electrical connections installed by a trained and qualified
electrician.
Observe regulations IEC60364.
DANGER
Power supply not disconnected
Danger to life!
Pull the mains plug or disconnect all electrical connections and secure against
unintentional start-up.
The pump (set) remains installed
ü Sufficient fluid is supplied for the functional check run of the pump.
1. For prolonged shutdown periods, start up the pump (set) regularly between
once a month and once every three months for approximately five minutes.
ð This will prevent the formation of deposits within the pump and the pump
intake area.
The pump (set) is removed from the pipe and stored
ü The pump has been properly drained. (ðSection7.3,Page23)
ü The safety instructions for dismantling the pump have been observed.
1. Spray-coat the inside wall of the pump casing and, in particular, the impeller
clearance areas with a preservative.
2. Spray the preservative through the suction nozzle and discharge nozzle.
It is advisable to then close the pump nozzles (e.g. with plastic caps).
3. Oil or grease all exposed machined parts and surfaces of the pump (with
silicone-free oil or grease, food-approved if required) to protect them against
corrosion.
Observe the additional instructions on preservation.
If the pump set is to be stored temporarily, only preserve the wetted components
made of low-alloy materials. Commercially available preservatives (food-approved, if
required) can be used for this purpose. Observe the manufacturer's instructions for
application/removal.
Observe any additional instructions and information provided. (ðSection3,Page10)
6.4 Returning to service
For returning the equipment to service observe the sections on commissioning/start-
up and the operating limits. (ðSection6.1,Page20) (ðSection6.2,Page20)
In addition, carry out all servicing/maintenance operations before returning the
pump (set) to service. (ðSection7,Page23)
WARNING
Failure to re-install or re-activate protective devices
Risk of injury from moving parts or escaping fluid!
As soon as the work is completed, properly re-install and re-activate any safety-
relevant devices and protective devices.