Qtech QSW-3200-28FC [132/136] Configure link monitoring

Qtech QSW-3200-28T [132/136] Configure link monitoring
+7(495) 797-3311www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1
121
For example:
! Configure response timeout to be 5s
QTECH(config-if-ethernet-0/1)#EFM remote-response-timeout 5
20.2.7 Configure link monitoring
Configure it in interface configuration mode:
Configure window and threshold in errored-symbol-period
EFM link-monitor errored-symbol-period window high win-value1 low win-value2
EFM link-monitor errored-symbol-period threshold high th-value1 low th-value2
Parameter :
window: received symbol number (8 byte) ,which is in the range of 10xffffffffffffffff. The default
is 10000.win-value1 and win-value2 represent 4 high bytes and low bytes.
threshold: received error symbol number (8 bytes) ,which is in the range of 10xffffffffffffffff.
The default is 1,th-value1 and th-value2 represent 4 high bytes and low bytes.
Configure window and threshold in errored-frame
EFM link-monitor errored-frame window win-value
EFM link-monitor errored-frame threshold th-value
Parameter:
win-value: received time,which is in the range of 10(100ms)600(100ms). The default is
10(100ms)
th-value: received failure frame number, which is in the range of 10xffffffff. The default is 1
Configure window and threshold in errored-frame-period
EFM link-monitor errored-frame-period window win-value
EFM link-monitor errored-frame-period threshold th-value
Parameter:
win-value: received frame number which is in the range of 10xffffffff. The default is 10000
th-value: received failure frame number, which is in the range of 10xffffffff. The default is 1
Configure window and threshold in errored-frame-seconds
EFM link-monitor errored-frame-seconds window win-value
EFM link-monitor errored-frame-seconds threshold th-value
Parameter:
win-value: received time,which is in the range of 100(100ms)9000(100ms). The default is
600(100ms)
th-value: received failure second, which is in the range of 1900. The default is 1
Restore to default link monitoring configuration
no EFM link-monitor { errored-symbol-period | errored-frame | errored-frame-period | errored-
frame-seconds } window
no EFM link-monitor { errored-symbol-period | errored-frame | errored-frame-period | errored-
frame-seconds } threshold
For example:
! Configure window in errored-symbol-period to be 50000
QTECH(config-if-ethernet-0/1)#EFM link-monitor errored-symbol-period window high 0 low
50000