Qtech QSW-8200-52T-POEAC- DC [7/10] Commands for poe monitoring and debugging

Qtech QSW-8200-52T-POEAC- DC [7/10] Commands for poe monitoring and debugging
User Manual
Chapter 1. Commands for PoE 7
www.qtech.ru
Switch(Config-Ethernet1/0/2)#power inline priority critical
1.2 Commands for PoE Monitoring and Debugging
1.2.1 Monitoring and Debugging Information
1.2.1.1 show power inline
Command: show power inline
Function: Display global PoE configurations and status.
Parameters: None.
Command Mode: Admin Mode.
Default: None.
Usage Guide: The meanings of each field are listed in the following table:
Field
Description
Power Inline Status
The global PoE status: enabled or disabled
Power Available
The global max value of available power
Power Used
The global value of used power
Power Remaining
The global value of remaining power
Min Voltage
The global threshold of under-voltage
Max Voltage
The global threshold of over-voltage
Police
The power priority policy status: enabled or disabled
Legacy
The non-standard PD detection status: enabled or
disabled
Disconnect
The PD disconnection mode
HW Version
The hardware version of the PoE module
SW Version
The software version of the PoE module
Mode
Power supply mode

Похожие устройства