Qtech QSW-9000-01 [397/474] Bfd configuration

Превью страниц Страница 397 / 474
Qtech QSW-9000-01 [397/474] Bfd configuration
Manual
26. BFD Configuration 397
www.qtech.ru
26. BFD CONFIGURATION
26.1. BFD Configuration
ip ospf bfd
bfd min-transmit-interval value
bfd min-receive-interval value
bfd detect-multiplier value
bfd demand { on | off }
bfd session init-mode { passive | active}
clear bfd statistics
show bfd session [verbose]
show bfd interface [verbose]
26.1.1. Ip ospf bfd
Use this command to enable ospf bfd. Use no command to disable ospf bfd.
ip ospf bfd
no ip ospf bfd
Command configuration mode
vlan interface mode
Example
Enable ospf bfd in vlan interface 1
Optiway(config-if-vlanInterface-1)#ip ospf bfd
Disable ospf bfd in vlan interface 1
Optiway(config-if-vlanInterface-1)#no ip ospf bfd
26.1.2. Bfd min-transmit-interval value
Use this command to configure bfd min-transmit-interval.Use no command to restore default
min-transmit-interval.
bfd min-transmit-interval value
no bfd min-transmit-interval
Parameter
value:the mini transmit interval which is in the range of 222ms~1222ms and the default value
is 422ms