CITEL DLA-48DBC Инструкция по установке онлайн

(for all
versions)
Technical Data
Wiring Maintenance
Installation
DLA (/R)
DLAH (/R)
DLAW (/R)
DLAHW (/R)
DLU
DLU2
DLUH
DLUH2
X
and replace
with
DLAM-xxx, DLASM-xxx, DLAHM-xxx, DLAHWM-xxx (module)
or
DLU-xxx, DLUH-xxx (product)
X
X
X
and replace
with
DLAWM-xxx
X
X
X
Clip on
symmetrical
DIN rail
5 mm
0.2 in
0.5-2,5 mm²
#20-13 AWG
Drawing A : for DLA, DLAS, DLAH, DLAHW, DLA2 & DLAW
Drawing B : for DLU, DLUH, DLU2
&
DLUH2
Drawing C : for DLA/R, DLAS/
R
, DLAH/
R
, DLAHW/
R
& DLAW/
R
Specic versions: DLAW-xxx (/R) Standard versions: DLAx-xx (/R) , DLAS-xx(/R) & DLAUx-xx
Line cut-o in case of removal of plug-in module :
DLA2
A
B
#20-13 AWG
0.5-2.5 mm²
4
10 mm
0.4 in
10 mm
0.4 in
#15-13 AWG
1.5-2.5mm²
1
0.5 Nm
4.4 Lb-In
2
1.5-2.5mm²
#15-13 AWG
5 mm
0.2 in
2
33
5 mm
0.2 in
0.5-4 mm²
#20-11 AWG
#20-11 AWG
0.5-4 mm²
5 mm
0.2 in
3
2
5
4
0.5 Nm
4.4 Lb-In
NOTE :
DLAxx, DLASxx and DLA2xx surge protectors
must be connected to the bonding network
through one of the 3 connections points.
DLA (/R)
DLAH (/R)
DLAHW (/R)
DLA2
DLU
DLU2
Pair A (1 - 5)
Pair B (7 - 11)
1 3 5
7 9 11
8 10 12
246
DLA2
DIN rail
Pair B (8 - 12)
Pair A (2 - 6)
NOTE :
DLUxx surge protectors
must be connected to the bonding network
through one of the 3 connections points.
Line still on in case of removal plug-in module :
X
X
INSTALLATION INSTRUCTIONS -
NOTICE D'INSTALLATION
NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE
ISTRUZIONI PER L'INSTALLAZIONE
INSTRUCOES DE INSTALACAO - MONTÁŽNÍ NÁVOD
РУКОВОДСТВО ПО МОНТАЖУ - 安装指导书
Dataline surge protector
Parafoudre pour ligne de données
Proteccion para lineas datos
Überspannungsschutz für Datentechnik
Protezione per linee dati
Protetor de Surto para linha de dados.
DIN rail
1 2
1 2
3 4
3 4
DLU2
DLUH2
Pair A (1 - 2)
Pair B (3 - 4)
Pair B (3 - 4)
Pair A (1 - 2)
1 2
1 2
DLA (/R)**
DLAS (/R)
DLAH (/R)
DLAW (/R)
DLAHW (/R)
DIN rail
Pair A (1 - 2)
Pair A (1 - 2)
1 2
1 2
DLU
DLUH
DIN rail
Pair A (1 - 2)
Pair A (1 - 2)
N130502g
xxx*-170
DLA-PE
xxx*-48D3
xxx*-48DBC
xxx*-24D3
xxx*-24DBC
xxx*-12D3
xxx*-12DBC
xxx*-06D3
xxx*-06DBC
DLU2-24D2-10A
DLA-170G
8 V
For line grounding (no SPD)
28 V
36 V
15 V
53 V
170 V
Screw terminal
Spring terminal
0.3
2.5
DLA, DLAS, DLA2 , DLUD, DLU2
DLAH, DLAW, DLAHW, DLUH , DLUH2
xxx*-170/R
xxx*-48D3/R
xxx*-48DBC/R
xxx*-24D3/R
xxx*-24DBC/R
xxx*-12D3/R
xxx*-12DBC/R
xxx*-06D3/R
xxx*-06DBC/R
DLAH-32D3
6500 ft max.
2000 m ma
x.
-40/+185°F max.
-40/+85°C max.
IP20
indoor use only
2
10
xxx* = DLA, DLAS, DLAH, DLAW,DLAHW DLA2,
DLU, DLU2, DLUH or DLUH2
P/N
Max. DC operating voltage (Uc)
Max. line current IL (A)
Connection to Network
DLAS (/R)
DLAHW
X
DLAS (/R)
X
DLAS
RED
indicator
Humidity range
5% to 95%
C
5
6
1
2
3
4
3
4
Push
4
Push
(/R)** = spring terminal versions
X
X
Содержание
- 2 dla dlas dla2 dlud dlu2 1
- Clip on symmetrical din rail 1
- Connection to network 1
- Dataline surge protector 1
- Dla 170g 1
- Dlah 32d3 1
- Dlah dlaw dlahw dluh dluh2 1
- Dlu xx surge protectors must be connected to the bonding network through one of the 3 connections points 1
- Dlu2 24d2 10a 1
- Dluh2 drawing c for dla r dlas 1
- Drawing a for dla dlas dlah dlahw dla2 dlaw drawing b for dlu dluh dlu2 1
- For line grounding no spd 1
- Installation 1
- Installation instructions 1
- Line cut of in case of removal of plug in module 1
- Line still on in case of removal plug in module 1
- Max dc operating voltage uc 1
- Max line current 1
- N130502g 1
- Note dla xx dlas xx and dla2 xx surge protectors must be connected to the bonding network through one of the 3 connections points 1
- Notice d installation 1
- Noticia de instalación installationshinweise istruzioni per l installazione instrucoes de instalacao montážní návod руководство по монтажу 安装指导书 1
- Proteccion para lineas datos überspannungsschutz für datentechnik protezione per linee dati protetor de surto para linha de dados 1
- R spring terminal versions 1
- Red indicator 1
- Screw terminal 1
- Spring terminal 1
- Technical data 1
- Wiring maintenance 1
- Xxx 06d3 r xxx 06dbc r 1
- Xxx 170 dla pe 1
- Xxx 170 r 1
- Xxx 24d3 r 1
- Xxx 24dbc r xxx 12d3 r xxx 12dbc r 1
- Xxx 48d3 1
- Xxx 48d3 r xxx 48dbc r 1
- Xxx 48dbc xxx 24d3 xxx 24dbc xxx 12d3 xxx 12dbc xxx 06d3 xxx 06dbc 1
- Xxx dla dlas dlah dlaw dlahw dla2 dlu dlu2 dluh or dluh2 1
- Advertencia de seguridad 2
- Atencion 2
- Attention 2
- Attenzione 2
- Avisos importantes 2
- Avvertenze importanti 2
- Bezpečnostní pokyny 2
- Consignes de securite 2
- It es pt 2
- Rus varování 2
- Safety instructions 2
- Sicherheitshinweise 2
- Warnung 2
- Внимание 2
- Меры безопасности 2
- 中文 2
- 安全须知 2
Похожие устройства
- CITEL DLAH-06D3 Инструкция по установке
- CITEL DLAW-06D3 Инструкция по установке
- CITEL DLC-06DBC Инструкция по установке
- CITEL DLC-12D3 Инструкция по установке
- CITEL DLC-12DBC Инструкция по установке
- CITEL DLC-170 Инструкция по установке
- CITEL DLC-24D3 Инструкция по установке
- CITEL DLC-24DBC Инструкция по установке
- KSB Multitec RO MTC B 50/8D Инструкция по эксплуатации
- KSB Multitec RO MTC B 50/8D Технические данные
- CITEL DLC-48D3 Инструкция по установке
- CITEL DLC-48DBC Инструкция по установке
- KSB Multitec RO MTC B 50/8E Инструкция по эксплуатации
- KSB Multitec RO MTC B 50/8E Технические данные
- KSB Multitec RO MTC B 50/8F Инструкция по эксплуатации
- KSB Multitec RO MTC B 50/8F Технические данные
- KSB Multitec RO MTC B 50/8V Инструкция по эксплуатации
- KSB Multitec RO MTC B 50/8V Технические данные
- CITEL DLU-06D3 Инструкция по установке
- KSB Multitec RO MTC B 65/10A Инструкция по эксплуатации