Beurer JBY52 [12/48] Cleaning and maintenance

Beurer JBY52 [12/48] Cleaning and maintenance
12
Press the rapid heat-up button 1.
again to start the warming process.
The display now continuously shows the remaining warming time. The display starts to flash
one minute before the end of the warming process. The warming process stops once the
pre-specified warming time has elapsed. The heat LED and the display go out.
Starting the warming process without prior warming:
Press the 1.
button to switch the device on. The current temperature is shown on the
display. The default setting is 37 °C.
To enter the temperature, press the 2.
button repeatedly until you have reached the desired
temperature for keeping the food/drink warm (between 35 °C and 85 °C). The temperature
increases in the steps 37, 38, 40, 45, 50, 60, 70, 80 until the display reaches “85” and then
begins again at 35 °C.
Now press the 3.
button again to start the keeping warm process.
Ending the warming/keeping warm process:
Press the 1.
button for 2 seconds.
The display and the heater are switched o.
Remove the bottle/jar using the lifter.2.
Unplug the mains cable after each usage, pour all the water out and dry the device with a 3.
cloth.
Shake the bottle or stir the food in the jar.š
Check that it is the correct temperature. š
To prevent the breeding of bacteria, which multiply fastest in the temperature range š
from around 32°C to 42°C, please use the heated baby food as soon as possible.
We do not recommend keeping the food warm for any longer, as this can cause š
important vitamins to be lost.
For hygienic and microbiological reasons, do not reheat food that has already been š
heated.
Take care not to overheat food/liquids.š
8. Cleaning and maintenance
The service life of the device depends on its careful handling:
To extend the service life of the device, we recommend that it is not (continuously) operated š
in the high temperature range.
Use boiled or filtered water for warming baby food. This will reduce the build-up of lime š
scale.
Unplug the device before cleaning.š
To clean the device, use only a damp cloth. Do not use any scouring agents or other clean-š
ing products.
Descale the device using vinegar or citric acid. Place the lifter in the device, mix 50 ml of š
household vinegar with 100 ml of cold water or a packet of citric acid with 200 ml of cold
water and pour this solution into the device. Leave the solution to work until the lime scale
has been removed; do not operate the device during this time. Pour the liquid away, rinse
the device out thoroughly and finally dry it with a cloth.
Descale the device approx. every four weeks.š