Lowara 10SV 06K022 1015L120C [7/72] Version diagram

Lowara 10SV 05K022 1015L119C [7/72] Version diagram
7
CARATTERISTICHE
GENERALI
1
-
3
-
5
-
10
-
15
-
22
-
33
-
46
-
66
-
92
-
125
SV
2
POLI
50
H
z
Max efficiency flow (m³/h) 1,7 3 5,5 10,5 16,5 20,5 31 43 72 90 120
Flow range (m³/h) 0,7÷2,4 1,2÷4,4 2,4÷8,5 5÷14 8÷24 11÷29 15÷40 22÷60 30÷85 45÷120 60÷160
Maximum head ( m ) 230 250 250 250 250 260 300 360 230 210 220
Motor power ( kW ) 0,37÷2,2 0,37÷3 0,37÷5.5 0,75÷11 1,1÷15 1,1÷18,5 2,2÷30 3÷45 4÷45 5,5÷45 7,5÷55
Max η ( % ) of pump
50 60 70 71 72 73 77 79 78 80 78
Standard temperature ( °C )
1-125sv_2p50-en_b_tg
-30 +120
3SV 5SV 10SV1SV 15SV 22SV 125SV33SV 46SV 66SV 92SV
VERSIONI
33
-
46
-
66
-
92
-
125SV
33SV 46SV 66SV 92SV 125SV
G
CAST IRON PUMP CASING, LIQUID END MADE OF
STAINLESS STEEL, IN-LINE ROUND FLANGES
PN16, PN25 OR PN40 DEPENDING ON NUMBER OF
STAGES AND MODEL.
N
ALL AISI 316 STAINLESS STEEL, IN-LINE ROUND
FLANGES, PN16, PN25 OR PN40 DEPENDING ON NUMBER OF
STAGES AND MODEL.
P
ALL AISI 316 STAINLESS STEEL.
FLANGES,IN-LINE ROUND, PN40.
• = Available. For P versions see specific catalogue.
33-125sv_2p50-en_a_tc
•••
••
••
••
TYPE
2 POLES SV
••••
VERSION DIAGRAM
VERSIONI
1
-
22SV
1SV 3SV 5SV 10SV 15SV 22SV
F AISI 304, PN25. In-line ports, round flanges
••••••
T AISI 304, PN16. In-line ports, oval flanges
••••••
R AISI 304, PN25. Discharge port above suction, round flanges
••••••
N AISI 316, PN25. In-line ports, round flanges
••••••
V AISI 316, PN25. Victaulic® couplings
••••••
P AISI 316, PN40. Victaulic® couplings
••••••
C AISI 316, PN25. Clamp couplings (DIN 32676)
••••••
K AISI 316, PN25. Threaded couplings (DIN 11851)
••••••
• = Available. For P versions see specific catalogue.
1-22sv_2p50-en_b_tc
TYPE
2 POLES
1, 3, 5, 10, 15, 22SV VERSIONS
33, 46, 66, 92, 125SV VERSIONS
GENERAL CHARACTERISTICS
2-POLE SV

Содержание