Lowara FC E 65-160/55/P [22/132] Fc fc fc fc fcs fcts series s fcts series s fcts series s fcts series s fcts series three phase motors a three phase motors a three phase motors a three phase motors a three phase motors at 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles

Lowara FC TE 65-125/40/P [22/132] Fc fc fc fc fcs fcts series s fcts series s fcts series s fcts series s fcts series three phase motors a three phase motors a three phase motors a three phase motors a three phase motors at 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles t 50 hz 2 poles
22
FCFC
FCFC
FC
S-FCTS SERIESS-FCTS SERIES
S-FCTS SERIESS-FCTS SERIES
S-FCTS SERIES
THREE-PHASE MOTORS ATHREE-PHASE MOTORS A
THREE-PHASE MOTORS ATHREE-PHASE MOTORS A
THREE-PHASE MOTORS A
T 50 Hz, 2 POLEST 50 Hz, 2 POLES
T 50 Hz, 2 POLEST 50 Hz, 2 POLES
T 50 Hz, 2 POLES
MOTORI TRIFASE PER SERIE FCS FCTS 50 Hz, 2 poli
P
N
kW 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4 4/4 3/4 2/4
0,75 82,5 83,1 81,3 82,8 82,7 80,1 82,6 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9 82,5 82,0 78,9
1,1 84,0 84,7 83,4 84,4 84,5 82,5 84,3 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4 84,0 84,0 81,4
1,5 85,6 86,5 85,8 85,9 86,4 84,9 86,0 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0 85,6 86,0 84,0
2,2 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7 83,7
3 85,5 86,8 85,6 86,1 86,8 85,6 86,3 86,8 85,6 85,5 86,8 85,6 85,5 86,8 85,6 85,5 86,8 85,6
4 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3 86,3
5,5 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6 87,6
7,5 88,6 88,1 88,1 88,6 88,1 88,1 88,6 88,1 88,1 88,6 88,1 88,1 88,6 88,1 88,1 88,6 88,1 88,1
11 90,3 91,1 90,3 90,3 91,1 90,3 90,3 91,1 90,3 90,3 91,1 90,3 90,3 91,1 90,3 90,3 91,1 90,3
15 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3 90,3
18,5 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2 91,2
22 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3 91,3
P
N
f
N
kW Hz
0,75 80
1,1 80
1,5 90R
2,2 90
3 100R
4 112R
5,5 132R
7,5 132
11 160R
15 160
18,5 160
22 180R
ATEX
P
N
220 V 230 V 240 V 380 V 400 V 415 V 380 V 400 V 415 V 660 V 690 V
kW
0,75 2,96 2,94 2,96 1,71 1,70 1,71 1,70 1,69 1,70 0,98 0,98
1,1 4,19 4,14 4,16 2,42 2,39 2,40 2,41 2,38 2,38 1,39 1,37
1,5 5,56 5,49 5,51 3,21 3,17 3,18 3,21 3,18 3,19 1,85 1,84
2,2 8,05 8,04 8,09 4,65 4,64 4,67 4,62 4,61 4,63 2,67 2,66
3 10,8 10,6 10,6 6,23 6,14 6,12 6,18 6,10 6,06 3,57 3,52
4 13,6 13,5 13,5 7,88 7,77 7,79 7,80 7,63 7,65 4,51 4,41
5,5 18,3 18,0 17,9 10,6 10,4 10,3 10,6 10,4 10,5 6,14 6,02
7,5 25,4 24,8 24,4 14,7 14,3 14,1 14,5 14,0 13,9 8,35 8,11
11 36,0 35,1 34,7 20,8 20,3 20,0 20,8 20,3 20,1 12,0 11,7
15 47,2 45,3 44,0 27,2 26,2 25,4 27,2 26,0 25,3 15,7 15,0
18,5 58,3 56,9 55,9 33,7 32,9 32,3 34,1 33,2 32,8 19,7 19,1
22 68,3 66,2 64,3 39,4 38,2 37,1 40,0 38,6 37,8 23,1 22,3
* R = Reduced size of motor casing as compared to shaft extension and flange.
fcs-fcts-ie2-mott-2p50-en_b_te
** Operating conditions to be referred to motor only. About electric pump, refer to limits in user’s manual.
PLM180RB5/3220
PLM90B5/322
PLM100RB5/330
PLM112RB5/340
PLM132RB5/355
PLM132B5/375
PLM160RB5/3110
PLM160B5/3150
PLM160B5/3185
Manufacturer
SM80B5/307PE
SM80B5/311PE
SM90RB5/315PE
Manufacturer
Lowara srl Unipersonale
Reg. No. 341820260
Montecchio Maggiore Vicenza - Italia
B5
Altitude
Above Sea
Level (m)
502
0,78
0,79
0,80
0,80
No
T. amb
min/max
°C
0,82
0,85
0,91
0,88
0,87
0,87
0,87
IEC SIZE*
N. of
Poles
Data for 400 V / 50 Hz Voltage
cosϕ
T
N
Construction
Design
3,74 3,71
3,57 3,75
3,953,958,31
7,38 2,48
9,50 71,1
3,63
10,3 18,1
2,74 4,26
8,80
8,63 7,25
4,96 4,31 4,10
8,39 9,96
IE
ls / l
N
Nm
Ts/T
N
Tm/Tn
Y 690 V
By June 2011
3
2
3,50 3,32
9,52 13,1 3,04 4,40
4,43 5,80
4,55
9,72 36,0 3,46 4,56
9,21 24,5 3,26
2,26 3,81
9,75 59,8 2,82 4,53
8,45 48,6
0,89
Efficiency η
N
Year of
manufacture
%
220 V 230 V 240 V 380 V 400 V 415 V
Y 380 V Y 400 V Y 415 V Y 660 V
Operating conditions **
Voltage U
N
V
Y
Observe the regulations and codes locally
in force regarding sorted waste disposal.
1000 -15 / 40
I
N
(A)
Y
n
N
2850 ÷ 2885
2895 ÷ 2920
2885 ÷ 2905
min
-1
2875 ÷ 2895
2870 ÷ 2900
2870 ÷ 2895
2885 ÷ 2900
2945 ÷ 2955
2920 ÷ 2935
2910 ÷ 2925
2940 ÷ 2950
2945 ÷ 2955

Содержание

Похожие устройства

Скачать