Problem Possible cause Remedy
The vacuum pump
becomes extreme-
ly hot and swit-
ches off.
Insuf cient supply of cooling air
Ensure that the vacuum pump coo-
ling system is not hampered by
dust/dirt.
Clean the ventilation grille,
Maintain the distance speci ed bet-
ween the air vent slits and the wall
Mains frequency or mains power
supply outside the tolerance range
Establish a stable power supply
Ambient temperature higher than
40 °C
Stop work
Clamping not pos-
sible.
Button valve on the suction plate
faulty
Clean the button valve (see 8 Ser-
vice and maintenance)/
Replace the button valve.
Slide valve [6-1]
stiff.
Valve sleeve [6-2] dirty
Clean the valve sleeve and apply a
light coat of grease