Festool VAC SYS SE 1 580061 [18/110] Fault correction

Festool VAC SYS SE 1 580061 [18/110] Fault correction
18
13 Fault correction
Warning
All maintenance and repair work on the pump must be carried out
by an authorised service workshop only.
Problem Possible cause Remedy
Required vacuum
is not attained, in-
dicator on the va-
cuum gauge [1-3]
in red sector.
Vacuum gauge faulty
Replace the vacuum gauge
(Festool Service)
Vacuum pump faulty
Repair or replace the vacuum pump
(Festool Service)
Hose and/or pipe connections are
not tight
Check the connections for leaks
Air lter partly blocked Replace the air lter
More than 2000 m above sea level
Slide valve worn
Change the slide valve
(Festool Service)
Clamping unit not connected Connect the clamping unit
Clamping unit not seated correctly
on the base surface
Seat the clamping unit correctly on
the base surface
Unsuitable base surface
(not airtight or at)
Use a suitable base
Rubber seal underneath the contact
surface shows signs of damage
Replace the rubber seal
Foot valve faulty
Replace the foot valve
(Festool Service)
Insuf cient vacu-
um during opera-
tion.
Vacuum hose faulty or leaking
Replace the vacuum hose; replace
the hose connector if necessary
Vacuum pump faulty
Repair or replace the vacuum pump
(Festool Service)
When using the clamping unit
VAC SYS SE:
Clamping unit does not form a seal
with the clamping plate
Suction cup on the workpiece not
completely sealed
Stop work immediately and remove
the workpiece
Check the clamping plate and suc-
tion cup
The vacuum pump
does not start.
Drive motor is overloaded or con-
nected to incorrect mains voltage
Connect the drive motor to the cor-
rect mains voltage
Vacuum pump faulty
Repair or replace the vacuum pump
(Festool Service)
Mains cable is too small or too long
Use a mains cable with suf cient di-
mensions
The vacuum pump
seizes.
Solid foreign matter has entered
the vacuum pump
Contact Festool Service
Slide valve broken
Replace the slide valve
(Festool Service)
The vacuum pump
makes excessive
noise or rattles
during operation.
Loose mains connection(s)
Tighten or replace loose connec-
tions.
Foreign objects in the vacuum
pump
Faulty bearings or worn slide valves
Contact Festool Service

Содержание