3.6 Permitted Nozzle Loads and Torques
at the Pump Nozzles ...
... following the Europump-Recommendation for
pump acc. to ISO 5199.
The data for forces and torques are only valid for static
piping loads and are valid for one nozzle.
All values for forces and torques refer to standard
material 0.6020.
Valid for the pump hanging in the piping
Size
Pump Nozzles
DN
Forces [N] Torques [Nm]
Fx Fy Fz
F
Mx My Mz
M
100-125 100 1500 1675 1350 2625 875 625 725 1300
100-160 100 1500 1675 1350 2625 875 625 725 1300
125-160 125 1775 1975 1600 3100 1050 750 950 1525
125-200 125 1775 1975 1600 3100 1050 750 950 1525
150-200 150 2250 2500 2025 3925 1250 875 1025 1825
150-250 150 2250 2500 2025 3925 1250 875 1025 1825
200-200 200 3000 3350 2700 5225 1625 1150 1325 2400
200-250 200 3000 3350 2700 5225 1625 1150 1325 2400
200-270 200 3000 3350 2700 5225 1625 1150 1325 2400
200-315 200 3000 3350 2700 5225 1625 1150 1325 2400
250-315 250 3725 4175 3375 6525 2225 1575 1825 3275
250-350 250 3725 4175 3375 6525 2225 1575 1825 3275
250-400 250 3725 4175 3375 6525 2225 1575 1825 3275
300-350 300 4475 5000 4025 7825 3025 2150 2475 4450
300-400 300 4475 5000 4025 7825 3025 2150 2475 4450
300-450 300 4475 5000 4025 7825 3025 2150 2475 4450
300-480 300 4475 5000 4025 7825 3025 2150 2475 4450
Valid for the pump standing on the support foot
Size
Pump Nozzles
DN
Forces [N] Torques [Nm]
Fx Fy Fz
F
Mx My Mz
M
100-125 100 1125 1260 1020 1970 625 375 475 870
100-160 100 1125 1260 1020 1970 625 375 475 870
125-160 125 1330 1480 1200 2325 800 500 700 1175
125-200 125 1330 1480 1200 2325 800 500 700 1175
150-200 150 1690 1875 1520 2950 1000 625 775 1410
150-250 150 1690 1875 1520 2950 1000 625 775 1410
200-200 200 2250 2520 2025 3920 1375 900 1075 1970
200-250 200 2250 2520 2025 3920 1375 900 1075 1970
200-270 200 2250 2520 2025 3920 1375 900 1075 1970
200-315 200 2250 2520 2025 3920 1375 900 1075 1970
250-315 250 2800 3130 2530 4900 1975 1325 1575 2860
250-350 250 2800 3130 2530 1900 1975 1325 1575 2860
250-400 250 2800 3130 2530 1900 1975 1325 1575 2860
300-350 300 3360 3750 3020 5870 2775 1900 2225 4040
300-400 300 3360 3750 3020 5870 2775 1900 2225 4040
300-450 300 3360 3750 3020 5870 2775 1900 2225 4040
300-480 300 3360 3750 3020 5870 2775 1900 2225 4040
3.7 Permitted pressures and temperatures
Basically the values, regarding pressures and
temperatures, given in the data sheet and / or the
order confirmation, as well as on the name plate are
valid. Exceeding or remaining under of these values
are undue. If there are no pressures and / or
temperatures mentioned in data sheet and / or order
confirmation, the following limits are valid for suction
pressure and room temperature:
Suction pressure (System pressure) = Pressure at
pump suction: max. 5 bar
Ambient temperature max. 40°C.
On application of pumps local laws and regulations
must be noticed, as well (e.g. DIN 4747 or DIN 4752,
section 4.5).