Installation, Operation and Maintenance Instruction
Model LER, LERS, LEZ
LER 100-english page 5
Revision 01
Article No 771073302
Issue 01/2010
2.7.2 Permitted Nozzle Loads and Torques
Basically the suction and discharge piping must
be designed in such way, that as little forces as
possible are effective to the pump. If that is not
possible, the values shown in chapter 3.5 must
not be exceeded under any circumstances. Thi
s
is valid for the operation as well as for the
standstill of the pump and therefore for all
pos
sible pressures and temperatures of the
unit.
2.7.3 NPSH
The pumped liquid must have a min. pressure
NPSH at the impeller inlet; so that cavitations
free w
ork is secured resp. a "break off" of the
pump flow is prevented. This condition is
fulfilled, when NPSH-
value of the system
(NPSHA) lies above NPSH-
value of the pump
(NPSHR) under all operating conditions.
Attention must especially be paid to the NPSH-value
on pumping liquids near the vapour pressure. If the
NPSH-value of the pump remains under, this can lead
from damage of the material due to cavitations to
destruction by overheating.
The NPSH-value of the pump (NPSHR) is shown in
the curves of every pump type.
2.7.4 Back Flow
In systems where pumps are operating in closed
circuits under pressure (gas cushions, steam
pressure), the pressure of the gas cushion must not
be reduced via the pump, since the back flow speed
may be much higher than the operating speed, which
would destroy the unit.
3. Description
3.1 Design
The pumps of Model LER, LERS and LEZ are single-
stage In-line pumps with suction and discharge nozzle
„in-line“ with identical pipe diameter and a common
end-to-end pump-motor-shaft (Mono-Block-Design).
Model LER and LERS:
In-line pump with closed radial impeller in block design
with attached motor.
Model LEZ:
In-line pump with closed radial impeller in block design
with attached motor.
The model LEZ is a twin pump with 2 identical driving
units, common pump casing and an integrated flap
valve on discharge side.
These pumps are not qualified for dangerous
or
inflammable fluids. Not qua
lified for the
operation in areas subject to explosion hazards.
The permitted application conditions and design
details of the delivered pump are shown in the
attached data sheet and / or the order confirmation
(see Design Coding System in chapter 3.2).
3.1.1 Solids
In general the models LER, LERS and LEZ are suited
to handle a limited number of solids. Whether or not it
can handle a given application largely depends on the
abrasive nature, the concentration and the solid size of
the solids.
It is not allowed to exceed a solid concentration of 25
mg/l up to max. 50 mg/l and a solid size of 0,1 mm up
to max. 0,3 mm. But inside these limits it must be
calculated with higher wear depending on the abrasive
nature of the solids.
3.1.2 Viscosity Limits
In general these models are capable of pumping
viscous liquids. The maximum viscosity limit is appr.
100 cP.
3.1.3 Installation position
The small pump units up to 15 kW motor power can
get installed directly without support foot in the piping,
but for safety reasons the motor arrangement down
respectively the terminal box down is not allowed.
A support foot must be used for big pumps. For the
condition of the base frame see chapter 5.1.
The appropriate sectional drawing of the supplied
pump as well as the complete weight of the pump unit
is shown in the appendix.
3.2 Design Coding System
Due to the coding on data sheet and / or order
confirmation all information regarding der delivered
pump can be found in this Installation, Operation and
Maintenance Instruction, e.g.:
LER 250 - 400 U1 N L 900 4
(0)
(1) (2) (3)
(4) (5) (6)
(7)
Position (0) - Name of the basic Model:
LER - Single unit up to 10 bar / 120 °C
LERS - Single unit up to 16 bar / 150 °C
LEZ - Twin unit up to 10 bar / 120 °C
Position (1) - Suction and discharge nozzle in mm
Position (2) - Nominal impeller diameter in mm
Position (3) - Design of the shaft sealing
Single mechanical seal acc. DIN 24960 l1k /
EN 12756 Form U, unbalanced
Exception: ∅18- and ∅32mm seals are not
acc. DIN 24960 l1k / EN 12756; ∅75mm
PN16 seal is form "B", balanced
Содержание
- En vogel volute casing pumps model ler lers lez 1
- Ec declaration of conformity 2
- Installation operation and maintenance instructio 4
- Model ler lers lez 4
- Table of contents 4
- Installation operation and maintenance instructio 5
- Model ler lers lez 5
- Name plate 5
- General 6
- Guarantee 6
- Installation operation and maintenance instructio 6
- Marking of references in the 6
- Model ler lers lez 6
- Operating instructions 6
- Safety regulations 6
- Dangers of non observance of the safety instructions 7
- Installation operation and maintenance instructio 7
- Model ler lers lez 7
- Safety instructions for maintenance inspections and mounting work 7
- Safety instructions for the operator worker 7
- Unauthorized alteration and spare parts production 7
- Undue operation 7
- Use acc to regulations 7
- Description 8
- Design 8
- Design coding system 8
- Installation operation and maintenance instructio 8
- Model ler lers lez 8
- Approximate value for sound 9
- Are valid for pump and motor sound pressure level 9
- Bearing 9
- During installation push the mech seals with a bellows in such a way that the bellows is compressed and not stretched danger of tearing apart 9
- Especially the seal faces must be clean dry and undamaged don t apply lubrication on the seal faces of the mech seal 9
- Have all required parts prepared so that assembly can be completed quickly the lubricants are only effective for a short time after that the axial mobility and thus the automatic adjustment of the elastomers are lost 9
- If a lubricant is provided with the replacement mech seal you should use this 9
- Installation operation and maintenance instructio 9
- Ler 100 english page 6 9
- Measured in 1 m distance from pump surface acc to din 45635 part 1 and 24 room and foundation influences are not considered the tolerance for these values is 3 db a addition with 60 hz operation pump alone pump with motor 4 db a 9
- Model ler lers lez 9
- Never push elastomers over sharp edges if necessary use mounting devices 9
- Pay attention to the utmost cleanness 9
- Pressure level 9
- Revision 01 article no 771073302 issue 01 2010 9
- Shaft sealing 9
- Sound pressure level 9
- Structure of the mechanical seal this shaft seal is a single mech seal with installation dimensions according to en 12756 din 24960 form u no additional flushing of the seal chamber is necessary the seal casing where the mechanical seal is located must always be filled with liquid for a description of materials and operational ranges of the mech seals supplied please refer to the data sheet in the operation instructions and order confirmation for the internal structure of the mechanical seal see the following sectional drawings 3 general information 9
- The reuse of mech seals that have already been used for a longer time can lead to leaking at the seal faces after reinstallation therefore the replacement of the mech seal with a new one is recommended the removed mechanical seal can be reconditioned by the manufacturer and serve as a replacement mech seal 3 information for the mounting 9
- The shaft is guided by the ball bearings of the motor the bearings are grease lubricated for life and therefore maintenance free 9
- The specified values fort he sound pressure level 9
- U1 carbon silicon carbide epdm bq1egg exception 65 and 75mm seal carbon ceramics epdm u2 carbon silicon carbide viton bq1vgg u3 silicon carbide silicon carbide viton q1q1vgg position 4 impeller material n cast iron 0 020 l ductile iron 0 040 only for pump size dn 300 position 5 pump casing material n cast iron 0 020 l ductile iron 0 040 other materials are not available position 6 motor power in 1 10 kw position 7 number of motor contacts 2 pole 2900 rpm 4 pole 1450 rpm 6 pole 950 rpm 9
- Use mineral grease or oil only if you are completely sure that the elastomers of the mech seal are oil resistant use no silicone 9
- Use only lubricants with which you are certain use only lubricants with which you are certain that no dangerous reaction can occur between the lubricant and the pumped medium 9
- Basically the values regarding pressures and temperatures given in the data sheet and or the order confirmation as well as on the name plate are valid exceeding or remaining under of these values are undue if there are no pressures and or temperatures mentioned in data sheet and or order confirmation the following limits are valid for suction pressure and room temperature 10
- Following the europump recommendation for pump acc to iso 5199 the data for forces and torques are only valid for static piping loads and are valid for one nozzle all values for forces and torques refer to standard material 0 020 10
- Installation operation and maintenance instructio 10
- Ler 100 english page 7 10
- Model ler lers lez 10
- Permitted nozzle loads and torques at the pump nozzles 10
- Permitted pressures and temperatures 10
- Suction pressure system pressure pressure at pump suction max 5 bar ambient temperature max 40 c on application of pumps local laws and regulations must be noticed as well e g din 4747 or din 4752 section 4 10
- Valid for the pump hanging in the piping valid for the pump hanging in the piping 10
- Valid for the pump standing on the support foot 10
- Installation operation and maintenance instructio 11
- Model ler lers lez 11
- Mounting installation 11
- Mounting of pump unit 11
- Storage conservation 11
- Transport handling 11
- Transport handling storage 11
- Connection of piping to the pump 12
- Electric connection 12
- Final check 12
- Initial start up 12
- Installation operation and maintenance instructio 12
- Model ler lers lez 12
- Start up operation shut down 12
- Installation operation and maintenance instructio 13
- Limits of operation 13
- Lubrication 13
- Model ler lers lez 13
- Monitoring 13
- Restarting 13
- Switch on drive 13
- Cleaning of pump 14
- Dismantling and repair of pump 14
- General remarks 14
- Installation operation and maintenance instructio 14
- Mechanical seals 14
- Model ler lers lez 14
- Motor bearings 14
- Servicing maintenance 14
- Shutting down 14
- Storage longer periods of non operation 14
- Faults causes and solutions 15
- General 15
- Installation operation and maintenance instructio 15
- Model ler lers lez 15
- Spare parts 15
- Spare parts spare pumps 15
- Stand by pumps 15
- Installation operation and maintenance instructio 16
- Ler 100 english page 13 16
- Model ler lers lez 16
- Revision 01 article no 771073302 issue 01 2010 16
- Installation operation and maintenance instructio 17
- Model ler lers lez 17
- Installation operation and maintenance instructio 18
- Model ler lers lez 18
- Complete unit motor power 19
- Installation operation and maintenance instructio 19
- Ler 100 english page 16 19
- Ler lers 1450 mi 19
- Ler lers 2900 mi 19
- Ler lers 970 mi 19
- Lez 1450 mi 19
- Lez 2900 mi 19
- Lez 970 mi 19
- Model ler lers lez 19
- Revision 01 article no 771073302 issue 01 2010 19
- Weight 19
- Weights 19
Похожие устройства
- Lowara LEZ 125-200 UNL 3702 Технические характеристики
- Lowara LEZ 200-200 UNL 1104 Инструкция по эксплуатации
- Lowara LEZ 200-200 UNL 1104 Технические характеристики
- Lowara LEZ 200-200 UNL 556 Инструкция по эксплуатации
- Lowara LEZ 200-200 UNL 556 Технические характеристики
- Lowara LEZ 200-250 UNL 1504 Инструкция по эксплуатации
- Lowara LEZ 200-250 UNL 1504 Технические характеристики
- Lowara LEZ 200-250 UNL 1854 Инструкция по эксплуатации
- Lowara LEZ 200-250 UNL 1854 Технические характеристики
- Lowara LEZ 200-250 UNL 2204 Инструкция по эксплуатации
- Lowara LEZ 200-250 UNL 2204 Технические характеристики
- Lowara LEZ 200-250 UNL 556 Инструкция по эксплуатации
- Lowara LEZ 200-250 UNL 556 Технические характеристики
- Lowara LEZ 200-270 UNL 3004 Инструкция по эксплуатации
- Lowara LEZ 200-270 UNL 3004 Технические характеристики
- Lowara LEZ 200-270 UNL 756 Инструкция по эксплуатации
- Lowara LEZ 200-270 UNL 756 Технические характеристики
- Lowara LEZ 200-315 UNL 1106 Инструкция по эксплуатации
- Lowara LEZ 200-315 UNL 1106 Технические характеристики
- Lowara LEZ 200-315 UNL 3704 Инструкция по эксплуатации