Steinel HL 1920 E [14/161] Hl 1920 e

Steinel HL 1920 E [14/161] Hl 1920 e
- 13 -
Keeping the button pressed will continue to increase or re-
duce the temperature in steps of 10 °C until the rocker but-
t
on is released or the minimum or maximum temperature is
set. The temperature setting is shown on the display for
3
seconds. On lowering or increasing the temperature, the
actual temperature is then displayed at the delivery nozzle.
T
he °C/°F symbol flashes during this period. As soon as the
selected temperature is reached, this symbol stops flashing
and is displayed all the time. Blower stage 1 delivers a tem-
p
erature of 80 °C. When the tool has been operating at high
temperatures on blower stage 2 or 3 it will take a short while
t
o cool to 80 °C after switching down to blower stage 1.
While the tool is cooling down, the LCD display shows
t
he actual temperature at the nozzle outlet. After switching
off, the tool stays in the last setting that was selected. The
guard sleeve detaches at a bayonet catch.
Changing the power cord (HL 2020 E only)
If the power cord is damaged, it can easily be changed
without opening the casing.
1. Important! Disconnect tool from power supply.
2. Undo screw and remove cover cap .
3. Release cable grip .
4. Undo mains terminals .
5. Pull out cord .
6. Insert new cord and secure in reverse order
(1. Firmly screw down mains terminals etc.).
a
b
c
d
e
14
These hot air tools are doubly protected from overheating:
1
. A thermostat switches the heater off if too much of the
air outlet nozzle is obstructed (heat build-up). However,
t
he blower continues to run. A warning triangle on the
display tells you that the heater is switched off.
Once the air delivery nozzle is clear again, the heater au-
t
omatically switches back on again after a few moments.
The warning triangle then goes out. The thermostat may
a
lso respond after switching the hot air tool off, taking it
longer than usual to reach temperature at the air delivery
n
ozzle when it is switched on again. *
2. The thermal cut-out completely shuts down the tool if it is
overloaded.
* for HL 2020 E only
For your safety
Tool description - Operation
Please note: The distance from the object you are working
on depends on material and intended method of working.
Always try out the airflow and temperature on a test piece
first. Using the attachable accessory nozzles (see acces-
sories page on the cover) the flow of hot air can be con-
trolled with maximum precision. Take care when changing
hot nozzles! When using the hot air tool in the self-resting
position, make sure it is standing on a stable, non-slip and
clean surface.
HL 1620 S
The tool is switched on and off at the two-stage switch
on the back of the grip handle. Airflow and temperature can
be adjusted to 2 settings. Stage 1 reaches 300 °C at an
airflow of 240 l/min, stage 2 reaches 500 °C at 450 l/min.
This tool is intended for home use only.
HL 1920 E
The tool is switched on and off at the two-stage switch
on the back of the grip handle. In addition to three-stage
speed/airflow control (stage 1 is a cold-air stage at 80 °C),
temperature can be continuously adjusted over a range of
80 °C – 600 °C in settings 2 and 3 at the thumbwheel .
The numbers 1 - 9 on the thumbwheel serve as a guide
only. Whereas "1" means 80 °C, the maximum temperature
of 600 °C is attained at "9". Airflow can be adjusted to the
three stages of 150 / 150-300 / 300-500 l/min. The guard
sleeve detaches at a bayonet catch.
HL 2020 E
The tool is switched on and off at the two-stage switch
on the back of the grip handle. In addition to three-stage
speed/airflow control at the switch , temperature can be
continuously adjusted over a range of 80 °C to 630 °C in
settings 2 and 3 at the rocker switch . The target temper-
ature can be increased in 10 °C increments by pressing the
right-hand "+" side of the rocker switch or reduced by
pressing the left-hand "–" side of the rocker switch .
GB
7
8
3
7
7
9
9
10
3
7
9

Содержание

Скачать