Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
As the battery pack ages, even if it is looked after, its ca-
pacity reduces such that the full run time will no longer
be reached when fully charged. This does not indicate a
defect.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Subject to technical modifications.
Vibration value
WARNING
The specified vibration value was measured using a
standard test procedure and may be used to compare
devices.
The specified vibration value may be used in a provi-
sional assessment of the load.
Depending on the way the device is used, the vibration
emission can deviate from the specified overall value
during the current use of the device.
Device with a hand-arm
vibration value > 2.5 m/s² (see
chapter Technical Data in the
operating instructions)
CAUTION ● Uninterrupted
use of the device for several
hours can lead to numbness.
Wear warm gloves to protect
your hands. ● Take regular
breaks from work.
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: Hedge trimmer
Type: HGE 18-50 Battery 1.444-24x.0
Currently applicable EU Directives
2000/14/EC (+2005/88/EC)
2014/30/EU
2006/42/EC (+2009/127/EC)
2011/65/EU
Harmonised standards used
EN 50581: 2012
Fault Cause Rectification
The device does not start
up
Battery pack is not inserted correctly. Push the battery pack into the mounting
until it latches into place.
The device does not start
up
Battery pack is empty Charge the battery pack.
The device does not start
up
Battery pack is defective. Replace the battery pack.
The device stops during
operation
Blade blocked with cutting material. Remove cutting material from the blade.
The device stops during
operation
The battery has overheated Stop working and allow the battery to cool
down to normal battery temperature.
The device stops during
operation
Motor has overheated Stop working and allow the motor to cool
down.
Device performance data
Working voltage of the battery V 18
Idling speed (normal setting) /min 1350 +/-
10%
Cut material diameter (max.) mm
22
Determined values in acc. with EN 60745-1, EN
60745-2-15
Sound pressure level L
pA
dB(A) 80,2
Uncertainty K
pA
dB(A) 3,0
Sound power level L
WA
+ K uncer-
tainty
WA
dB(A) 93
Front handle hand-arm vibration
value
m/s
2
0,2
Rear handle hand-arm vibration
value
m/s
2
0,2
Uncertainty K m/s
2
1,5
Dimensions and weights
Length x width x height mm 970 x
213 x
188
Cutting blade length mm 500
Weight (without battery pack) kg 2,7