Dimplex Synergy [13/24] Fireplace installation
13
Figure 9
Key-hole
Wall stud
Permanent
mounting hole
the partially reective glass to
fall out of the inside framing.
CAUTION: Partially reective
glass is not tempered. Do not
bump or drop the partially reec-
tive glass to avoid breakage and
personal injury.
Remove partially reective
glass from replace.
4. Position the replace on a wall
at the position where it will be
mounted (Figure 9). Use a
bubble level (one is supplied)
to ensure that replace is level
on the wall.
5. Ensuring that at least two
key-holes line up with a wall
stud (key-holes are spaced
at 4 in. (10.2 cm) centers),
mark the location of four screw
Fireplace Installation
locations on the wall (through
key-holes).
6. Remove fireplace from wall
and store in a safe place away
from traffic.
7. Where marked screw locations
do not line up with a wall stud,
insert (screw in) one of the two
supplied wall anchors (predrill
if required). Repeat if only two
screws line up with a wall stud.
8. Screw all four supplied #8,
1½ in. (3.8 cm) square head
mounting screws and wash-
ers into the wall and/or wall
anchors leaving ¼ in. (6.5 mm)
of thread.
9. Align chosen key-holes with
screws and hang replace on
the wall. Screw heads and
washers will t through key-
holes and replace will slide
down into place (screws will
slide into narrow part of key-
holes).
10. Tighten all four mounting
screws down on replace
chassis.
11. Screw the two supplied #8
square head screws through
two of the permanent mount-
ing holes which align with a
wall stud.