4.1 Error Code
Cha
pter
4
Troubleshooting Guide
(4-way valve swich failure)
No. Error Code Problem
1
E1
Room temperature sensor fault
2
E2
Outdoor coil temperature sensor fault
3
E3
Indoor coil temperature sensor fault
4
E4
Indoor fan motor or DC motor feedback fault
5
E5
Indoor & outdoor communication fault
6
F0
Outdoor DC Fan motor fault
7
F1
IPM modular fault
8
F2
PFC modular fault
9
F3
Compressor operation fault
10
F4
Exhaust Temperature sensor fault
11
F5
Compressor top cover protection
12
F6
Outdoor ambient temp sensor fault
13
F7
Over/under voltage protection
14
F8
Outdoor modular communication fault
15
F9
Outdoor E²PROM fault
16
FA
Suction temperature sensor fault
Содержание
- For split wall 1
- Model type for 1
- Mounted 1
- Series r410a inverter 1
- Split type room air conditioner 1
- Contents 2
- Indoor unit 4
- Outdoor unit 4
- Outline dimensions 4
- Capillary throttling 5
- Chapter 2 refrigeration diagrams 5
- Compressor compression 5
- Cooling cycle 5
- Cooling mode 5
- Cooling only 5
- Indoor heat exchanger evaporation 5
- Liquid of low pressure liquid of low pressure gas of high pressure also a little gas temperature 5
- Outdoor heat exchanger condensation 5
- Steam gas of low pressure 5
- Super cooled liquid super cooled liquid of high pressure 5
- Cooling cycle 6
- Cooling heating 6
- Cooling mode 6
- Heating cycle 7
- Heating mode 7
- Chapter 3 wiring diagram 8
- Electric chart for 09 12 18 24k 8
- Indoor unit 8
- Electric chart for 09 12 18k 9
- Outdoor unit 9
- Electric chart for 24k 10
- Outdoor unit 10
- Chapter 4 troubleshooting guide 11
- Error code 11
- The foremost inspecting items 12
- Troubleshooting guide 12
- No problems causes 13
- No power display 14
- The indoor fan motor does not work 15
- The outdoor unit does not work 16
- The step motor does not work 17
- Heating mode can work but no hot air blow 18
- ⑴ check if the set temperature is lower than the indoor temperature 18
- ⑵ check if the indoor pcb is connected to the terminal correctly 18
- Remote control can not work 19
- Trouble shooting rocedure 19
Похожие устройства
- Lanzkraft LSWH-50FL1Z/LSAH-50FL1Z Сервис мануал
- Lanzkraft LSWH-35FL1Z/LSAH-35FL1Z Сервис мануал
- Lanzkraft LSWH-25FL1Z/LSAH-25FL1Z Сервис мануал
- Daikin VAM150FA Электрическая схема подключения
- Daikin VAM150FA Руководство по монтажу
- Daikin VAM250FA Электрическая схема подключения
- Daikin VAM250FA Руководство по монтажу
- Daikin VAM350FB Руководство по эксплуатации
- Daikin VAM350FB Электрическая схема подключения
- Daikin VAM500FB Руководство по эксплуатации
- Daikin VAM500FB Электрическая схема подключения
- Daikin VAM650FB Руководство по эксплуатации
- Daikin VAM650FB Электрическая схема подключения
- Daikin VAM800FB Руководство по эксплуатации
- Daikin VAM800FB Электрическая схема подключения
- Daikin VAM1000FB Руководство по эксплуатации
- Daikin VAM1000FB Электрическая схема подключения
- Daikin VAM1500FB Руководство по эксплуатации
- Daikin VAM1500FB Электрическая схема подключения
- Daikin VAM2000FB Руководство по эксплуатации
Скачать
Случайные обсуждения