Daikin EWAPC14AJYNN [14/41] Specifications

Daikin EWAPC11AJYNN [14/41] Specifications
Chillers • R-407C • EWAP-AJYNN
1
3
Hydronic Systems • Chillers
14
3 Specifications
Compressor Type Semi-hermetic single screw compressor
Refrigerant oil charge l 28 28 28 28 28 28
Model Quantity 3 3 3333
Speed rpm 2950 2950 2950 2950 2950 2950
Sound Level Sound Power Cooling dBA 104 104 104 104 104 104
Sound
Pressure
Cooling dBA 81.5 81.5 81.5 81.5 81.5 81.5
Sound Pressure + OPRN dBA 76.0 76.0 76.5 76.5 77.0 77.0
Sound Pressure + OPLN dBA 72.5 73.0 73.0 73.0 73.5 73.5
Refrigerant
circuit
Refrigerant type R-407C
Refrigerant charge kg 190 200 210 220 230 240
No of circuits 333333
Refrigerant control Electronic expansion valve
Piping
connections
Evaporator water inlet/outlet Victaulic, diameter 273mm
Safety Devices High pressure (pressure switch)
Low pressure (pressure switch)
Condensation fan magneto-thermal
High discharge temperature on the compressor
Phase monitor
Star/delta transition failed
Low delta pressure between suction and discharge
Low pressure ratio
High oil pressure drop
Low oil pressure
Notes Nominal cooling capacity and power input are based on 12/7 °C entering/leaving water temp. and 35°C air ambient
temp. Power input is for the whole unit.
3-1 TECHNICAL SPECIFICATIONS
EWAP850AJYNN/A EWAP900AJYNN/A EWAP950AJYNN/A EWAPC10AJYNN/A EWAPC11AJYNN/A EWAPC12AJYNN/A
Capacity
(Eurovent
conditions
specified in
notes)
Cooling Nominal kW 854 954 1028 1124 1196 1253
Capacity Steps % stepless 12.5-
100
stepless 12.5-
100
stepless 12.5-
100
stepless 12.5-
100
stepless 12.5-
100
stepless 8.3-100
Nominal input
(Eurovent
conditions
specified in
notes)
Cooling kW 319 354 386 424 458 476
EER 2.67 2.69 2.66 2.65 2.61 2.63
ESEER 3.20 3.24 3.21 3.21 3.17 3.24
Casing Colour RAL7032
Dimensions Unit Height mm 2520 2520 2520 2520 2520 2520
Width mm 8010 8910 8910 9810 9810 11870
Depth mm 2230 2230 2230 2230 2230 2230
Weight Unit kg 5900 6170 6290 6525 6645 9050
Operating Weight kg 6185 6440 6560 6780 6900 9320
Water Heat
Exchanger
Minimum water volume in the system
(Formula)
The minimum water content per unit should be calculated with a certain approximation using this simplified formula:
Q= 35.83 X ( P(kW) / ? T(°C ) ) X ( 1/ N ) where : Q = minimum water content per unit expressed in litres P = minimum
cooling capacity of the unit expressed in kW ?T = evaporator entering / leaving water temperature difference
expressed in °C N = Number of compressors For more accurate determination of quantity of water, it is advisable to
contact the designer of the plant.
Air heat
exchanger
Type Lanced fins – internally spiral wound tubes
3-1 TECHNICAL SPECIFICATIONS EWAPC13AJYNN EWAPC14AJYNN EWAPC15AJYNN EWAPC16AJYNN EWAPC17AJYNN EWAPC18AJYNN