FEATURES AND BENEFITS
Low operating cost and extended operating life
This chiller range is the result of careful
design, aimed to optimize
the energy efficiency of the chillers, with the objective of bringing down operating costs and improving installation profita
bility,
effectiveness and economical management.
The chillers feature a high efficiency scroll compressor
s, large condenser coil surface area for maximum heat transfer and low discharge
pressure, advanced technology condenser fans and a 'plate to plate' evaporator with low refrigerant pressure drops.
Low operating sound levels Very low sound levels both at fu
ll load and part load conditions are achieved by the latest
compressor design and by a unique new fan that moves large volume of air at exceptionally low sound levels and by the virtual
ly
vibration-free operation.
Outstanding reliability
The chillers have
two truly independent refrigerant circuits, in order to assure maximum safety for any
maintenance, whether planned or not. They are equipped with hermetic orbiting scroll compressor complete with motor
over-temperature and over-current devices and protecti
on against excessive gas discharge temperature, a proactive control logic and
are full factory-run-tested to optimized trouble-free operation.
Superior control logic
The new MicroTech III controller provides an easy to use control environmental. The contro
l logic is
designed to provide maximum efficiency, to continue operation in unusual operating conditions and to provide a history of uni
t
operation. One of the greatest benefits is the easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications.
Code requirements – Safety and observant of laws/directives Units are designed and manufactured in
accordance with applicable selections of the following:
Construction of pressure vessel
Machinery Directive
Low Voltage
Electromagnetic Compatibility
Electrical & Safety codes
Manufacturing Quality Stds
97/23/EC (PED)
2006/42/EC
2006/95/EC
2004/108/EC
EN 60204–1 / EN 60335-2-40
UNI – EN ISO 9001:2004
Certifications Units are CE marked, complying with European directives in force,
concerning manufacturing and safety. On request
units can be produced complying with laws in force in non European countries (ASME, GOST, etc.), and with other applications,
such as
naval (RINA, etc.).
Versions This range is available in one version:
HIGH EFFICIENCY
6 sizes to cover a range 178 up to 336 kW with an EER up to 3.11 and an ESEER up to 4.31 (data referred to Standard Noise).
The EER (Energy Efficiency Ratio) is the ratio of the Cooling Capacity to the Power Input of the unit. The Power Input
includes: the
power input for operation of the compressor, the power input of all control and safety devices, the power input for fans.
The ESEER (European Seasonal Energy Efficiency Ratio) is a weighed formula enabling to take into account the variation
of EER with the
load rate and the variation of air inlet condenser temperature.
ESEER = A x EER100% + B x EER75% + C x EER50% + D x EER25%
K = Coefficient; T = Air inlet condenser temperature.
Sound configurations Standard, low and reduced sound configurations available as follows:
STANDARD SOUND
Condenser fan rotating at 900 rpm, rubber antivibration under compressor
LOW SOUND
Condenser fan rotating at 900 rpm, rubber antivibration under compressor, compressor sound enclosure.
REDUCED SOUND
Condenser fan rotating at 705 rpm, rubber antivibration under compressor, compressor sound enclosure.
Pagina 2 di 34
Содержание
- Air cooled scroll chillers 1
- Databook 1
- Ewaq e 1
- Performance according to en14511 1
- Certifications 2
- Code requirements safety and observant of laws directives 2
- Features and benefits 2
- Low operating cost and extended operating life 2
- Low operating sound levels 2
- Outstanding reliability 2
- Pagina 2 di 34 2
- Sound configurations 2
- Superior control logic 2
- Versions 2
- Cabinet and structure 3
- Compressor 3
- Condenser 3
- Condenser fans ø 800 3
- Electrical control panel 3
- Electronic expansion valve 3
- Evaporator plate heat exchanger 3
- General characteristics 3
- Pagina 3 di 34 3
- Refrigerant 3
- Refrigerant circuit 3
- General characteristics 4
- Pagina 4 di 34 4
- Supervising systems on request 4
- Options 5
- Options on request 5
- Pagina 5 di 34 5
- Standard options supplied on basic unit 5
- Options 6
- Pagina 6 di 34 6
- Capacity class in kw cooling 7
- Efficiency level 7
- Inverter 7
- Machine type 7
- Model series 7
- Nomenclature 7
- Pagina 7 di 34 7
- Refrigerant 7
- Sound level 7
- Ewaq e xs 8
- Pagina 8 di 34 8
- Technical specifications 8
- Ewaq e xl 9
- Pagina 9 di 34 9
- Technical specifications 9
- Ewaq e xr 10
- Pagina 10 di 34 10
- Technical specifications 10
- Electrical specifications 11
- Ewaq e xs 11
- Pagina 11 di 34 11
- Electrical specifications 12
- Ewaq e xl 12
- Pagina 12 di 34 12
- Electrical specifications 13
- Ewaq e xr 13
- Pagina 13 di 34 13
- Ewaq e xl 14
- Ewaq e xr 14
- Ewaq e xs 14
- Pagina 14 di 34 14
- Sound levels 14
- Operating limits 15
- Pagina 15 di 34 15
- Table 1 water heat exchanger minimum and maximum water δt 15
- Table 2 water heat exchanger fouling factors 15
- Operating limits 16
- Pagina 16 di 34 16
- Table 3 air heat exchanger altitude correction factors 16
- Table 4 minimum glycol percentage for low air ambient temperature 16
- Table 5 available fan static pressure correction factors 16
- Operating limits 17
- Pagina 17 di 34 17
- Water charge flow and quality 17
- Water content in cooling circuits 17
- Cooling performance 19
- Ewaq e xs 19
- Pagina 19 di 34 19
- Cooling performance 20
- Ewaq e xs 20
- Pagina 20 di 34 20
- Cooling performance 21
- Ewaq e xl 21
- Pagina 21 di 34 21
- Cooling performance 22
- Ewaq e xl 22
- Pagina 22 di 34 22
- Cooling performance 23
- Ewaq e xr 23
- Pagina 23 di 34 23
- Cooling performance 24
- Ewaq e xr 24
- Pagina 24 di 34 24
- Options technical data 25
- Pagina 25 di 34 25
- Single pump 2 poles 25
- Water pump kit 25
- Options technical data 26
- Pagina 26 di 34 26
- Twin pump 2 poles 26
- Water pump kit combination matrix 26
- Options technical data 27
- Pagina 27 di 34 27
- Water pump kit technical information 27
- 2 3 4 5 6 7 8 28
- A m l i h g b c f e d 28
- Compressor evaporator condenser coil electrical panel fan evaporator water inlet evaporator water outlet slot for power and control panel connection 28
- Dimensional drawing 28
- Legend 28
- Pagina 28 di 34 28
- Handling 29
- Installation notes 29
- Location 29
- Pagina 29 di 34 29
- Space requirements 29
- Warning 29
- Acoustic protection 30
- Installation notes 30
- Pagina 30 di 34 30
- Storage 30
- Condenser coil 31
- Dimensions 31
- Evaporator phe 31
- General 31
- Pagina 31 di 34 31
- Performance 31
- Refrigerant 31
- Sound level and vibrations 31
- Technical specifications 31
- Unit description 31
- Condensation control 32
- Condenser fans 32
- Controller 32
- Electrical control panel 32
- Hydronic kit options on request 32
- Low sound unit configurations on request 32
- Pagina 32 di 34 32
- Refrigerant circuit 32
- Technical specifications 32
- Controller main features 33
- High level communications interface on request 33
- Pagina 33 di 34 33
- Technical specifications 33
Похожие устройства
- Daikin EWAQ320E-XL Инструкция по эксплуатации
- Daikin EWAQ340E-XL Руководство по эксплуатации
- Daikin EWAQ340E-XL Технические данные
- Daikin EWAQ340E-XL Инструкция по эксплуатации
- INTERTOOL AT-3014 Инструкция
- Daikin EWAQ170E-XR Руководство по эксплуатации
- Daikin EWAQ170E-XR Технические данные
- Daikin EWAQ170E-XR Инструкция по эксплуатации
- Daikin EWAQ190E-XR Руководство по эксплуатации
- Daikin EWAQ190E-XR Технические данные
- Daikin EWAQ190E-XR Инструкция по эксплуатации
- Daikin EWAQ220E-XR Руководство по эксплуатации
- Daikin EWAQ220E-XR Технические данные
- Daikin EWAQ220E-XR Инструкция по эксплуатации
- INTERTOOL AT-3012 Инструкция
- Daikin EWAQ260E-XR Технические данные
- Daikin EWAQ260E-XR Руководство по эксплуатации
- Daikin EWAQ260E-XR Инструкция по эксплуатации
- Daikin EWAQ300E-XR Технические данные
- Daikin EWAQ300E-XR Руководство по эксплуатации