Daikin EWAQ320E-XL [6/34] Options
![Daikin EWAQ320E-XL [6/34] Options](/views2/1661364/page6/bg6.png)
OPTIONS
Compressor thermal overload relays - Safety electronic devices
that, added to the standard protection devices, protect
compressor motors against overload and current unbalance.
Phase monitor - Device that monitors input voltage and stops the chiller in case of phase loss or wrong phase sequence.
Under / Over voltage control - Electronic device that monitors and displays input voltage, and stops the chiller in case of phase
loss, wrong phase sequence, or voltage exceeding minimum and maximum allowed values.
Energy meter - Device installed inside th
e control box that displays all chiller electrical power parameters at line input such as line
voltage and phase current,
input active and reactive power, active and reactive energy. An integrated RS485 module allows a
Modbus communication to an external BMS.
Capacitors for power factor correction - Devices that increase the power factor of the unit. The capacitors are “dry”
self-regenerating type with over pressure disconnecting safety device insulated with a no toxic dielectric mix without PCB or PCT.
Speedtrol (fan speed control device - ON/OFF - up to -18°C) - Continuous fan speed regulation on the first fan (VFD driven) of
each circuit. It allows unit operation down to -18ºC.
Setpoint reset, Demand limit and Alarm from external device - Setpoint Reset: The leaving water temperature set-point can
be overwritten with an external 4-20mA, through the ambient temperature, or through the evaporator water temperature ΔT.
Demand Limit: Chiller capacity can be limited through an external 4-20mA signal or via
network. Alarm from external device: The
unit controller is able to receive an external alarm signal. The user can decide whether this alarm signal will stop the unit or not.
Compressors circuit breakers Safety devices that include in a single device all safety functions otherwise provided by standard
fuses and optional thermal relays, such as protection against overcurrent, overload, current unbalance.
Fans circuit breakers - Safety devices that, added to the standard protection devices, protect fan motors against overload and
overcurrent.
Fans speed regulation (+ fan silent mode) - Continuous fan speed regulation of all fans (VFD driven) for improved sound level of
the unit during l
ow ambient temperature operation. At very low temperatures, all fans except the first are switched off thus allowing
unit operation down to -18°C.
INSTALLATION
Rubber anti vibration mounts - Supplied separately, these are positioned under the base of the
unit during installation. Ideal to
reduce the vibrations when the unit is floor mounted.
Spring anti vibration mounts - Supplied separately, these are positioned under the base of the unit during installation. Ideal for
dampening vibrations for installation on roofs and metallic structures.
External tank without cabinet (500 L)
External tank without cabinet (1000 L)
External tank with cabinet (500 L)
External tank with cabinet (1000 L)
OTHER
Container Kit
Witness test
Acoustic test
Pagina 6 di 34
Содержание
- Air cooled scroll chillers 1
- Databook 1
- Ewaq e 1
- Performance according to en14511 1
- Certifications 2
- Code requirements safety and observant of laws directives 2
- Features and benefits 2
- Low operating cost and extended operating life 2
- Low operating sound levels 2
- Outstanding reliability 2
- Pagina 2 di 34 2
- Sound configurations 2
- Superior control logic 2
- Versions 2
- Cabinet and structure 3
- Compressor 3
- Condenser 3
- Condenser fans ø 800 3
- Electrical control panel 3
- Electronic expansion valve 3
- Evaporator plate heat exchanger 3
- General characteristics 3
- Pagina 3 di 34 3
- Refrigerant 3
- Refrigerant circuit 3
- General characteristics 4
- Pagina 4 di 34 4
- Supervising systems on request 4
- Options 5
- Options on request 5
- Pagina 5 di 34 5
- Standard options supplied on basic unit 5
- Options 6
- Pagina 6 di 34 6
- Capacity class in kw cooling 7
- Efficiency level 7
- Inverter 7
- Machine type 7
- Model series 7
- Nomenclature 7
- Pagina 7 di 34 7
- Refrigerant 7
- Sound level 7
- Ewaq e xs 8
- Pagina 8 di 34 8
- Technical specifications 8
- Ewaq e xl 9
- Pagina 9 di 34 9
- Technical specifications 9
- Ewaq e xr 10
- Pagina 10 di 34 10
- Technical specifications 10
- Electrical specifications 11
- Ewaq e xs 11
- Pagina 11 di 34 11
- Electrical specifications 12
- Ewaq e xl 12
- Pagina 12 di 34 12
- Electrical specifications 13
- Ewaq e xr 13
- Pagina 13 di 34 13
- Ewaq e xl 14
- Ewaq e xr 14
- Ewaq e xs 14
- Pagina 14 di 34 14
- Sound levels 14
- Operating limits 15
- Pagina 15 di 34 15
- Table 1 water heat exchanger minimum and maximum water δt 15
- Table 2 water heat exchanger fouling factors 15
- Operating limits 16
- Pagina 16 di 34 16
- Table 3 air heat exchanger altitude correction factors 16
- Table 4 minimum glycol percentage for low air ambient temperature 16
- Table 5 available fan static pressure correction factors 16
- Operating limits 17
- Pagina 17 di 34 17
- Water charge flow and quality 17
- Water content in cooling circuits 17
- Cooling performance 19
- Ewaq e xs 19
- Pagina 19 di 34 19
- Cooling performance 20
- Ewaq e xs 20
- Pagina 20 di 34 20
- Cooling performance 21
- Ewaq e xl 21
- Pagina 21 di 34 21
- Cooling performance 22
- Ewaq e xl 22
- Pagina 22 di 34 22
- Cooling performance 23
- Ewaq e xr 23
- Pagina 23 di 34 23
- Cooling performance 24
- Ewaq e xr 24
- Pagina 24 di 34 24
- Options technical data 25
- Pagina 25 di 34 25
- Single pump 2 poles 25
- Water pump kit 25
- Options technical data 26
- Pagina 26 di 34 26
- Twin pump 2 poles 26
- Water pump kit combination matrix 26
- Options technical data 27
- Pagina 27 di 34 27
- Water pump kit technical information 27
- 2 3 4 5 6 7 8 28
- A m l i h g b c f e d 28
- Compressor evaporator condenser coil electrical panel fan evaporator water inlet evaporator water outlet slot for power and control panel connection 28
- Dimensional drawing 28
- Legend 28
- Pagina 28 di 34 28
- Handling 29
- Installation notes 29
- Location 29
- Pagina 29 di 34 29
- Space requirements 29
- Warning 29
- Acoustic protection 30
- Installation notes 30
- Pagina 30 di 34 30
- Storage 30
- Condenser coil 31
- Dimensions 31
- Evaporator phe 31
- General 31
- Pagina 31 di 34 31
- Performance 31
- Refrigerant 31
- Sound level and vibrations 31
- Technical specifications 31
- Unit description 31
- Condensation control 32
- Condenser fans 32
- Controller 32
- Electrical control panel 32
- Hydronic kit options on request 32
- Low sound unit configurations on request 32
- Pagina 32 di 34 32
- Refrigerant circuit 32
- Technical specifications 32
- Controller main features 33
- High level communications interface on request 33
- Pagina 33 di 34 33
- Technical specifications 33
Похожие устройства
- Daikin EWAQ320E-XL Инструкция по эксплуатации
- Daikin EWAQ340E-XL Руководство по эксплуатации
- Daikin EWAQ340E-XL Технические данные
- Daikin EWAQ340E-XL Инструкция по эксплуатации
- INTERTOOL AT-3014 Инструкция
- Daikin EWAQ170E-XR Руководство по эксплуатации
- Daikin EWAQ170E-XR Технические данные
- Daikin EWAQ170E-XR Инструкция по эксплуатации
- Daikin EWAQ190E-XR Руководство по эксплуатации
- Daikin EWAQ190E-XR Технические данные
- Daikin EWAQ190E-XR Инструкция по эксплуатации
- Daikin EWAQ220E-XR Руководство по эксплуатации
- Daikin EWAQ220E-XR Технические данные
- Daikin EWAQ220E-XR Инструкция по эксплуатации
- INTERTOOL AT-3012 Инструкция
- Daikin EWAQ260E-XR Технические данные
- Daikin EWAQ260E-XR Руководство по эксплуатации
- Daikin EWAQ260E-XR Инструкция по эксплуатации
- Daikin EWAQ300E-XR Технические данные
- Daikin EWAQ300E-XR Руководство по эксплуатации