12
Maximum Open Circuit Voltage: 700mV (3V for 200MΩ range).
Note: On 200MΩ range, if short input, the display will read 1MΩ, this 1MΩ should be subtracted
from measurement results.
Overload Protection: 250V dc or 250V ac rms
4.5 DIODE/CONTINUITY
Range Description
Diode Shows the approximate forward voltage drop
Continuity The built-in buzzer will sound, if the resistance under test is less than
about 70Ω
Overload Protection: 250V dc or 250V ac rms
5. BATTERY &
&&
& FUSE REPLACEMENT
If the sign“ ”appears on the LCD display, it indicates that battery should be replaced.
Remove screws on the back cover and open the case (see the right photo). Replace the exhausted
battery with a new one.
The fuse rarely needs replacement and blows almost always as a result of the operator’s error.
Open the case as mentioned above, and then take the PCB out from the front cover. Replace the
blown fuse with same ratings.
WARNING
Before attempting to open the case, be sure that test leads have been disconnected from
measurement circuits to avoid electric shock hazard.
For protection against fire, replace fuse only with specified ratings: F 200mA/250V
Содержание
- Ax t520 1
- Contents 2
- Warning to ensure safe operation and in order to exploit to the full functionality of the meter please follow the directions in this section carefully 3
- Caution do not use on the circuits as it may damage the tester 8
- Accuracy is specified for a period one year after calibration and at 18 º c to 28 º c 64 º f to 82 º f with relative humidity to 80 9
- Connect the remote unit to the other end of the cable 9
- Connect the rj45 test jack to one end of the cable to be tested 9
- Dimension 185 85 44 mm 9
- Fig miswire 9
- Fig reversed 9
- Fig right pass 9
- Fig short 9
- Fig split pairs 9
- Fuse protection ma f 200ma 250v 10a no 9
- General 9
- Maximum voltage 1000v dc or 700v ac 9
- Operating temperature 0 º c to 40 º c 32 º f to 104 º f 9
- Pair 1 2 pair 3 6 pair 4 5 pair 7 8 shie and sho will display at the same time 9
- Power supply 9v battery neda 1604 or 6f22 9
- Push test button again pair 1 2 pair 3 6 and sho will display continue to push test button the next pairs will display 9
- Push test button to perform test example the cable fault is a short on pair 1 2 and pair 3 6 the lcd status will be as follows 9
- Specifications 9
- Storage temperature 10 º c to 50 º c 14 º f to 122 º f 9
- Weight 360g including battery 9
Похожие устройства
- AXIOMET AX-PDM01 Инструкция
- Daikin EUWYN5KAZW1 Технические данные
- AXIOMET AX-MS8250 Инструкция
- AXIOMET AX-MS8250 Расширенная инструкция
- Daikin EUWYN5KAZW1 Руководство по эксплуатации
- Daikin EUWYP5KAZW1 Технические данные
- Daikin EUWYP5KAZW1 Руководство по эксплуатации
- Daikin EUWYB5KAZW1 Технические данные
- Daikin EUWYB5KAZW1 Руководство по эксплуатации
- Daikin EUWYN8KAZW1 Технические данные
- Daikin EUWYN8KAZW1 Руководство по эксплуатации
- Daikin EUWYP8KAZW1 Технические данные
- Daikin EUWYP8KAZW1 Руководство по эксплуатации
- AXIOMET AX-MS8221B Инструкция
- Daikin EUWYB8KAZW1 Руководство по эксплуатации
- Daikin EUWYB8KAZW1 Технические данные
- Daikin EUWYN10KAZW1 Технические данные
- Daikin EUWYN10KAZW1 Руководство по эксплуатации
- Daikin EUWYP10KAZW1 Руководство по эксплуатации
- AXIOMET AX-MS8221A Инструкция