Fluke FLK-113 [15/17] Model 113 english instruction sheet page 15
Model 113 English Instruction Sheet
Page 15
Maximum Voltage
Between any Terminal
and Earth Ground:
600 V
Display: 3 3/4-digits, 6000 counts, updates 4/sec
Operating Temperature: -10C to 50C (14F to 122F)
Storage Temperature: -40C to 60C (-22F to 140F)
Temperature
Coefficient:
0.1 x (specified accuracy)/C (<18 C or
>28 C)
Operating Altitude: 2,000 m
Storage Altitude: 10,000 m
Relative Humidity: 95 % to 30 C
75 % to 40 C
45 % to 50 C
Battery Type: 9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery Life: Alkaline: 300 hours typical, without
backlight
Shock: 1 Meter drop per IEC 61010-1-2001
Vibration: Per MIL-PRF-28800 for Class 2
instrument
Size (H x W x L): 6.58 in X 3.35 in X 1.81 in (167.1 mm X
85.1 mm X 46.0 mm)
Weight: 13.0 oz (404 g)
Safety: Complies with ANSI/ISA 82.02.01 (61010-
1) 2004, CAN/CSA-C22.2 No 61010-1-04,
UL 61010-1 (2004) and IEC/EN 61010-1
2
nd
Edition for measurement Category IV,
600 V, Pollution Degree 2, EMC
EN61326-1. S/N >17610000
EMI Regulations: Complies with FCC Part 15, Class B
Certifications:
TUV, (N10140), UL and VDE
Содержание
- Electrical multimeter 1
- Instruction sheet 1
- Model 113 english instruction sheet page 1 1
- Safety information 1
- Model 113 english instruction sheet page 2 2
- Automatic range selection 3
- Model 113 english instruction sheet page 3 3
- Symbols 3
- Terminals 3
- Backlight 5
- Battery saver sleep mode 5
- Display hold 5
- Model 113 english instruction sheet page 5 5
- Warning 5
- Function power up options are canceled when you turn the meter off and when sleep mode is activated 6
- Model 113 english instruction sheet page 6 6
- Power up options 6
- To select a power up option hold down the button indicated in the following table while turning the meter from off to the 6
- Ac and dc voltage 7
- Chek can be effectively used to eliminate ghost voltages 7
- Model 113 english instruction sheet page 7 7
- Model 113 english instruction sheet page 10 10
- Min max min max 12
- Model 113 english instruction sheet page 12 12
- Disabling the beeper disabling the beeper 13
- Maintenance 13
- Model 113 english instruction sheet page 13 13
- Accuracy specifications are given as follows 14
- Model 113 english instruction sheet page 14 14
- Of reading number of least significant digits 14
- Specifications 14
- Specifications are subject to change without notice 14
- Model 113 english instruction sheet page 15 15
- Min max recording accuracy and response time 16
- Model 113 english instruction sheet page 16 16
- Model 113 english instruction sheet page 17 17
Похожие устройства
- Fluke FLK-114 Инструкция по эксплуатации
- Fluke FLK-114 Технические характеристики
- Fluke FLK-114 Расширенная инструкция
- Fluke FLK-115 Инструкция по эксплуатации
- Fluke FLK-115 Технические характеристики
- Fluke FLK-115 Расширенная инструкция
- Fluke FLK-116 Инструкция по эксплуатации
- Fluke FLK-116 Технические характеристики
- Fluke FLK-116 Расширенная инструкция
- Fluke FLK-117 Инструкция по эксплуатации
- Fluke FLK-117 Технические характеристики
- Fluke FLK-117 Расширенная инструкция
- Fluke FLK-1577 Инструкция по эксплуатации
- Fluke FLK-1577 Технические характеристики
- Fluke FLK-1577 Расширенная инструкция
- Fluke FLK-1587FC Инструкция по эксплуатации
- Fluke FLK-1587FC Расширенная инструкция
- Fluke FLK-1587FC Технические характеристики
- Fluke FLK-175 Инструкция по эксплуатации
- Fluke FLK-175 Технические характеристики