Uni-T UT213A [7/20] Environmental limitation

UNI UT213A B C INSTRUCTIONS 2 Environmental Limitation Working environment Indoor use Maximum altitude 2 000m Safety regulations IEC EN 61010 1 IEC EN 61010 2 032 IEC EN 61010 2 033 CAT III 600V Pollution grade 2 Operating temperature and humidity 0 C 30 C not larger than 80 RH 30 C 40 C not larger than 75 RH 40 C 50 C not larger than 45 RH Storage temperature and humidity 20 C 60 C not larger than 80 RH 3 Electrical Specification Accuracy reading word count calibration period is a year Ambient temperature 23 C 5 C Ambient humidity 75 RH Temperature coefficient 0 1x accuracy C 1 AC current À UT213A B C INSTRUCTIONS UT213A B frequency response 50Hz 60Hz UT213C frequency response 40Hz 400Hz 2 DC current Ä Only for UT213C Measurement Range Resolution Ratio 40 00A 0 01A 400 0A 0 1A Accuracy 2 0 3 3 AC voltage v Measurement Range Resolution Ratio 4 000V 0 001V 40 00V 0 01V 400 0V 0 1V 600V 1V Accuracy 1 2 5 value applicable to 10 to 100 of the measurementrange Voltage input impedance SMOMQ Frequency response 40Hz 400Hz 4 000A only for UT213A B 0 001A 2 5 30 4 DC voltage v 40 00A 0 01A 2 5 5 Measurement Range Resolution Ratio Accuracy 400 0mV 0 1mV 1 0 8 0 1A 1 8 9 UT213A B 2 5 5 UT213C 4 000V 0 001V 0 8 1 40 00V 0 01V 400 0V 0 1V 600V 1V Display UT213A average value UT213B C true virtual value applicable to 10 to 100 of the measurement range 9 600V 1 5 5 Accuracy 400 0A Overload Protection DC AC Resolution Ratio 400A 400A DCI base number shall be cleared by pressing ZERO key Measurement Range Overload Protection Overload Protection 0 8 3 1 0 3 Voltage input impedance 5M0M Q 10 Overload Protection 600V DC AC

Скачать