Uni-T UT216B [3/18] I overview
Содержание
- Contents 2
- I overview 3
- Iilsafety operation rules 3
- Open case inspection 3
- Iv eiectrical symbols 4
- And figure 3 5
- See figure 1 5
- V external construction 5
- Vi lcd display see figure 2 5
- Vii key functions 6
- Viii technical indicator 7
- Capacitance hf 9
- Diode test h 9
- Lo frequency hz ut216b c only 9
- Temperature c ut216c only 9
- Ut216a b 9
- Ut216c 9
- Ix instructions for measurement 10
- Operation 10
- Figure 15 18
- X maintenance and upkeep see 18
Похожие устройства
- Uni-T UT216C Инструкция по эксплуатации
- Uni-T UT216C Документация
- Uni-T UT216C Инструкция EN
- Uni-T UT216C Расширенная инструкция
- Uni-T UT216D Инструкция по эксплуатации
- Uni-T UT216D Документация
- Uni-T UT216D Инструкция EN
- Uni-T UT216D Расширенная инструкция
- Uni-T UT219E Инструкция по эксплуатации
- Uni-T UT219E Документация
- Uni-T UT219E Инструкция EN
- Uni-T UT219E Расширенная инструкция
- Uni-T UT219M Инструкция по эксплуатации
- Uni-T UT219M Документация
- Uni-T UT219M Инструкция EN
- Uni-T UT219M Расширенная инструкция
- Uni-T UT219DS Инструкция по эксплуатации
- Uni-T UT219DS Документация
- Uni-T UT219DS Инструкция EN
- Uni-T UT219DS Расширенная инструкция
UNI UT216A B C OPERATING MANUAL I Overview UT216A B C is a portable true 35 6 bit 6000 Counts auto range clamp ammeter with simulation bar The clamp ammeter centered by large scale integrated circuit analog digital converter featuring full function on screen display full range overload protection and unique appearance design has become a specific clamp ammeter with superior performance The clamp ammeter is applicable to following measurements AC DC voltage AC DC current UT216C only surge current UT216C only resistance diode circuit on off capacitance temperature UT216C only frequency UT216B C only data hold maximum minimum value measurement relative value measurement flashlight function VFC function NCV function under voltage display and automatic shutdown function The instruction manual includes relevant safety information and warning indication please read them carefully and strictly observes all warnings and notes A Warning Prior to using clamp meter please read relevant Safety operation guidelines carefully the UT216A B C OPERATING MANUAL 5 Warranty In case of shortage or damage please contact with your supplier protection impairment if used in a manner not specified by the manufacturer probe assemblies used for MAINS measurements CATII 1000V CATIII 600V according to IEC 61010 031 IILSafety operation rules Please note the warning signs and words Warning means the condition or action that may cause threat to user or damage to the instrument or equipment to be measured This Meter complies with EN 61010 1 61010 2 032 61010 2 033 Pollution Degree 2 Overvoltage Category CATII 1000V CATIII 600V and Double Insulation standards CONFORMS TO UL STD 61010 1 and IEC STD 61010 2 032 CERTIFIED TO CSA STD C22 2 NO 61010 1 and 61010 2 032 CThis product has been tested to the requirementsof CAN CSA C22 2 No 61010 1 second edition including Amendment 1 Unpack and take out the instrument please check carefully if the following attachments are complete or intact 1 An operating instruction manual 2 A test pen 3 K shaped temperature probe UT216C only 4 A bag CAT II Applicable to test and measuring circuits connected directly to utilization points socket outlets and similar points of the low voltage MAINS installation CAT III Applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation 1 Check the clamp ammeter and test pen before using guard against any damage or abnormal 1 2 11 Open case inspection