Uni-T UT216B [7/18] Viii technical indicator
Содержание
- Contents 2
- I overview 3
- Iilsafety operation rules 3
- Open case inspection 3
- Iv eiectrical symbols 4
- And figure 3 5
- See figure 1 5
- V external construction 5
- Vi lcd display see figure 2 5
- Vii key functions 6
- Viii technical indicator 7
- Capacitance hf 9
- Diode test h 9
- Lo frequency hz ut216b c only 9
- Temperature c ut216c only 9
- Ut216a b 9
- Ut216c 9
- Ix instructions for measurement 10
- Operation 10
- Figure 15 18
- X maintenance and upkeep see 18
Похожие устройства
- Uni-T UT216C Инструкция по эксплуатации
- Uni-T UT216C Документация
- Uni-T UT216C Инструкция EN
- Uni-T UT216C Расширенная инструкция
- Uni-T UT216D Инструкция по эксплуатации
- Uni-T UT216D Документация
- Uni-T UT216D Инструкция EN
- Uni-T UT216D Расширенная инструкция
- Uni-T UT219E Инструкция по эксплуатации
- Uni-T UT219E Документация
- Uni-T UT219E Инструкция EN
- Uni-T UT219E Расширенная инструкция
- Uni-T UT219M Инструкция по эксплуатации
- Uni-T UT219M Документация
- Uni-T UT219M Инструкция EN
- Uni-T UT219M Расширенная инструкция
- Uni-T UT219DS Инструкция по эксплуатации
- Uni-T UT219DS Документация
- Uni-T UT219DS Инструкция EN
- Uni-T UT219DS Расширенная инструкция
UNI UT216A B C OPERATING MANUAL and capacitance measurement Press again to exit relative value measurement mode Under DC current gear measurement mode short press to enter clearing mode LCD will display A press again to exit clearing mode When UT216B is at AC voltage gear long press this key to enter voltage frequency measurement Long press it again to exit voltage frequency measurement When UT216C is at AC current gear long press this key LCD will display RUSH to enter surge current measurement mode at this time range is manual AC 600Agear Long press again to exit surge current measurement manual mode turns to auto mode 5 FLIGHT Long press this key flashlight function is on Short press this key flashlight function is off VIII Technical indicator 1 General specification Liquid crystal display maximum display 6000 Polarity display auto positive and negative polarity display Overload display OL or OL Low voltage display Figure 1 indicates that batter voltage is lower than working voltage reminding replacing battery Sampling rate about 3 s Sensor type coil induction UT216A Hall effect sensor UT216B C 9 UT216A B C OPERATING MANUAL Test position error an additional reading error of 1 0 may be resulted when the power to be measured is not clamped at the center of clamp head Impact resistance strength 1m fall impact Maximum openness of clamp head diameter 30mm Maximum dimension of current conductor to be measured diameter 30mm Electromagnetic field impact the application of device near electromagnetic field may result in unstable display or inaccurate reading Power 3 AAA 1 5V zinc manganese batteries UT216A B 3 AAA 1 5V alkaline batteries UT216C Dimension 228mm 77mmx41mm Weight about 265g inclusive of battery 2 Environmental constraint Working height indoor Altitude 2000m Safety codes IEC61010 1 IEC61010 2 032 CATH 1000V CATIH 600V Pollution grade 2 Operating humidity and temperature 0 C 30 C not bigger than 80 RH 30 C 40 C not bigger than 75 RH 40 C 50 C not bigger than 45 RH Storage humidity and temperature 20 C 60 C not bigger than 80 RH 10