Uni-T UT219M [12/20] 页 12
Содержание
- Content 1
- Limited warranty liability 1
- Preface 1
- I overview 2
- Ii unpacking inspection 2
- Iii safe operation rules 2
- Iv features 4
- V electrical symbols 4
- Vi comprehensive specifications 5
- Vii overall configuration 5
- Viii lcd display ix knobs 6
- X buttons 7
- Measuring 8
- Xi operating instruction for 8
- 页 10 10
- 页 11 11
- 页 12 12
- 页 13 13
- 页 14 14
- 页 15 15
- Xii technical specifications 16
- 页 16 16
- 页 17 17
- Frequency 18
- In case of capacitance to be measured 1 pf it is suggested that the accuracy of measurement can be guaranteed only by using the rel measurement mode 18
- Mhz 1 vrms a 30 vrms 18
- Resistance measurement 8 capacitance measurement 18
- 页 18 18
- Xiii maintenance and repair 19
- 页 19 19
- 页 20 20
Похожие устройства
- Uni-T UT219DS Инструкция по эксплуатации
- Uni-T UT219DS Документация
- Uni-T UT219DS Инструкция EN
- Uni-T UT219DS Расширенная инструкция
- Uni-T UT220 Инструкция по эксплуатации
- Uni-T UT220 Документация
- Uni-T UT220 Инструкция EN
- Uni-T UT220 Расширенная инструкция
- Uni-T UT221 Инструкция по эксплуатации
- Uni-T UT221 Документация
- Uni-T UT221 Инструкция EN
- Uni-T UT221 Расширенная инструкция
- Uni-T UT222 Инструкция по эксплуатации
- Uni-T UT222 Документация
- Uni-T UT222 Инструкция EN
- Uni-T UT222 Расширенная инструкция
- Uni-T UT223A Инструкция по эксплуатации
- Uni-T UT223A Инструкция EN
- Uni-T UT233 Инструкция по эксплуатации
- Uni-T UT233 Инструкция по эксплуатации
UNI UT219E Operating Manual 5 Conductivity testing UT219E Operating Manual 2 Set the functional range switch to press SELECT button to select the measuring range of resistance and pa ra 11 e I ly connect the probes to both ends of the load to be measured If the resistance between both ends is less than 10 Q the circuit is considered as breakover the buzzer will sound continuously In case the resistance is more than 50 Q the buzzer will not give any sound 3 Read the value of resistance value of load for the circuit to be measured directly from the display Notes When inspecting the on line circuit conductivity turn off all power supplies in the circuit to be measured and discharge all residual charges on all capacitors before carrying out measurement For circuit conductivity measuring the open circuit voltage is about 3 2 V more or less 1 Insert the red probe into socket insert the black probe into COM socket 21 the range is 100 Q measurement Do not input DC or AC 30 V and more voltage to prevent from personal injury After completion of all measuring operation disconnect the probes from the tested circuit 22